Drain Water Heat Recovery device (DWHR) is a counter-flow heat exchanger which is designed to recover heat from warm greywater in buildings. In this study, the thermal performance of a DWHR device was experimentally investigated under transient and steady conditions using the effectiveness-number of transfer units, thermal resistances, and thermal response test methods. An empirical correlation of the falling film Nusselt number as a function of Reynolds number was obtained for Reynolds range of 310 – 1285. An actual operational effectiveness was introduced to consider the effect of the transient response of the DWHR device. Performance degradation of the DWHR device due to fouling was simulated. It was found that the effectiveness decreases by about 27% of its value at the clean condition if the mains-water is soft (hardness < 3.5 grains/gal), and the effectiveness decreases by 46% if the mains-water is very hard (hardness > 15 grains/gal).

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science
Department thesis:degree_department
School of Engineering
Grantor dc:publisher
University of Guelph
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Salama, Mohamed
Advisor dc:contributor.advisor
  • Elsharqawy, Mostafa

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10214/17726

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Salama, Mohamed. Investigating the Performance of a Falling-Film Drain Water Heat Recovery System. University of Guelph, 2020. http://hdl.handle.net/10214/17726