Low-Frequency Vibration Attenuation Using Multi Degree of Freedom Quasi-Zero Stiffness Systems
Abstract
dc:description.abstractLow-frequency vibration is harmful and difficult to attenuate due to resonance. Since the natural frequency of a system is directly proportional to stiffness, reducing stiffness is advantageous. However, there are limitations to how far stiffness can be reduced while supporting a given mass. The addition of multiple degrees of freedom (MDOF), as well as nonlinear springs displaying high static low dynamic (HSLD) stiffness have been shown to partially overcome these limitations. This thesis combines the two techniques and completes an in-depth mathematical and experimental investigation of MDOF HSLD stiffness isolators. MDOF HSLD stiffness systems are shown to provide superior performance compared to other passive isolators. The sensitivity of design parameters is investigated, and the isolator's applicability is showcased by incorporating it into a heavy equipment seat cushion. Friction within the seat is modeled using the Force Balance Friction Model and is shown to change the dynamics of the system substantially.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science
- Department thesis:degree_department
- School of Engineering
- Grantor dc:publisher
- University of Guelph
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Habegger, Janik
- Advisors dc:contributor.advisor
-
- Oliver, Michele
- Hassan, Marwan
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10214/26643