Back to search

University of Guelph

Assessment of the Effect of General Anesthesia and Mechanical Ventilation on Volume Kinetics of Crystalloid Fluid in Cats

Abstract

dc:description.abstract

Intravenous (IV) fluids are integral to patient care in veterinary medicine, playing important roles in resuscitation, rehydration, and the maintenance of homeostasis and perfusion. Current guidelines recommend individualized IV fluid prescriptions to avoid the risks of fluid overload; however, there remains a limited understanding of fluid disposition to provide evidence-based guidance in veterinary medicine. Volume kinetics allows IV fluids to be studied in a manner analogous to drug pharmacokinetics. This thesis uses volume kinetics to explore the impact of anesthesia and mechanical ventilation in healthy female cats. The volume kinetic study employed a three-armed crossover design that included the awake state, general anesthesia with spontaneous breathing, and general anesthesia with mechanical ventilation. Cats received a 20 mL/kg bolus of a balanced crystalloid (Plasma-Lyte A) over 15 minutes, followed by a continuous rate infusion of 5 mL/kg starting 30 minutes after the bolus and continuing until the end of the trial. The study revealed that general anesthesia decreased the return of fluid from the peripheral to the central compartment, lower Doppler blood pressure was associated with lower rates of elimination under general anesthesia, and mechanical ventilation increased the volume of the central compartment. These findings overall suggest that anesthesia and mechanical ventilation induce a fluid-retentive state. Further population kinetic studies may help identify other significant covariates that influence fluid behaviour, and investigation into the use of vasopressors may help distinguish the effects of blood pressure from those of anesthesia. To reduce iatrogenic anemia from frequent blood sampling during the study, a secondary research aimed to validate the use of a point-of-care hemoglobinometer, HemoCue® Hb 201+ (HC-201), in cats. HC-201 demonstrated excellent accuracy and agreement compared to a reference hematologic analyzer, the ADVIA 2120®, and showed excellent precision with minimal influence from anemia, leukocytosis, azotemia, lipemia, or venipuncture site. Samples with icterus and hemolysis were insufficient for analysis and could be an area for further study. Further investigations into HC-201 performance using arterial and capillary samples would also be interesting.

Degree

thesis:*
Name thesis:degree_name
Doctor of Veterinary Science
Department thesis:degree_department
Department of Clinical Studies
Grantor dc:publisher
University of Guelph

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sun, Yuqing
Advisors dc:contributor.advisor
  • Yiew, Xiu Ting
  • Bateman, Shane

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Chapter 2 (on HemoCue) has been accepted for publication and is currently planned to be published in September, but not fully published yet.

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sun, Yuqing. Assessment of the Effect of General Anesthesia and Mechanical Ventilation on Volume Kinetics of Crystalloid Fluid in Cats. University of Guelph, https://hdl.handle.net/10214/29109