Back to search

University of Guelph

Rapid E.coli Detection Using Thickness Shear Mode (TSM) Biosensors

Abstract

dc:description.abstract

This thesis focuses on the development and improvement of fast pathogen detection methods involving TSM biosensors. The approaches introduced in this thesis consist of two main parts. The first part involves two constructed TSM biosensors, which are used for pathogen detection based on density and viscosity change of the test media along with the growth of E.coli. This thesis attempts to optimize the test media and determine the functional components affecting the oscillation frequency and shortening the initial growth phase of E.coli – the lag phase. In the lag phase, E.coli cells adjust to the ambient environment, absorb the nutrients in the test media and increase in mass, but don’t divide. The second part of the experiments is based on a constructed immunoassay TSM system. The crystals used in these experiments are coated with anti-E.coli antibodies with PCDA vesicles and gold nanoparticles. As the combination of E.coli cells and anti-E.coli antibodies leads to a mass loading on the crystal, the oscillation frequency would decrease. Therefore, this thesis explores whether the combination of E.coli and anti-E.coli antibodies can lead to a measurable frequency shift, and how the initial E.coli concentration in water samples affects the output results. This thesis concludes that a mixture of 3g/100ml mFC broth with 0.6g/100ml gelatin may be a successful test media, which has a detection limit of E.coli in the range of 1.3 ×〖10〗^4 CFU/100ml~1.333 ×〖10〗^5 CFU/100ml. In applications using this test media, the frequency shift can be up to 1800 Hz in 6 hours when E.coli concentrations reach 6.889 x 109 CFU/100ml; however, procedures to shorten the lag phase, which accounts for the majority of the entire detection time, are needed to be resolved in future research. For the constructed immunoassay TSM system, a measurable frequency shift was determined to occur only when the E.coli concentration is high enough and up to the magnitude of 107 CFU/100ml. Therefore, the approaches based on immunoassay principle need to be modified and optimized at areas of future research.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science
Department thesis:degree_department
School of Engineering
Grantor dc:publisher
University of Guelph
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tao, Tao
Advisor dc:contributor.advisor
  • McBean, Edward

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Attribution 2.5 Canada
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10214/7485

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Tao, Tao. Rapid E.coli Detection Using Thickness Shear Mode (TSM) Biosensors. University of Guelph, 2013. http://hdl.handle.net/10214/7485