Abstract

dc:description.abstract

This study presents an evaluation of ammonia and particulate matter emission factors and control strategies used in the various poultry sectors (layer, broiler, and turkey). Also presented are two emission monitoring studies that determined the emissions from a broiler chicken facility and the effectiveness of poultry litter treatment (PLT) in a turkey grow-out barn. The majority of currently available emission factors in the literature were found not to be representative of the facilities that were studied. Using the US EPAs AP-42 emission factor rating system, the laying hen sector using deep pit manure storage, received a C (average) emission factor quality rating (A being the best). Laying hen facilities with manure belts, broiler chicken, and turkey sectors received quality ratings considered to be below average or poor. In addition, overall efficiencies for available control strategies were summarized in terms of ammonia and particulate matter control. The majority of the studies reviewed employed oversimplified measurement techniques and short study durations. A two story commercial broiler facility in Perth County, Ontario, Canada was continuously monitored for ammonia and particulate matter emissions. Overall barn emission factors for ammonia, PM10, and PM2.5 were calculated to be 175 g day-1 AU-1, 4.2 g day-1 AU-1, and 2.4 g day-1 AU-1, respectively. A two-story turkey grow-out facility that used PLT was continuously monitored for 2 production cycles for ammonia and particulate matter. The overall average reduction in ammonia emissions from use of PLT was found to be 57% lasting on average 11 days. The average ammonia emission factors for the control and treatment barns were 203±185 g day-1 AU-1 and 134±139 g day-1 AU-1, respectively. For PM10 and PM2.5, the control emission factors were calculated to be 9.80±2.44 g day-1 AU-1 and 4.73±2.19 g day-1 AU-1, respectively, and for the treatment barn were 6.51±2.59 g day-1 AU-1 and 2.67±2.54 g day-1 AU-1, respectively.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Department thesis:degree_department
School of Engineering
Grantor dc:publisher
University of Guelph
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wood, David
Advisor dc:contributor.advisor
  • Van Heyst, Bill

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10214/9224

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wood, David. The Evaluation of Ammonia and Particulate Matter Control Strategies for Poultry Production Facilities. University of Guelph, 2015. http://hdl.handle.net/10214/9224