Iowa State University - Thesis & Dissertation
Non-linear calibration of multi-set differential pulse voltammetry data and evaluation of a pairwise subtraction-based sampling method
Abstract
dc:description.abstractChemical reactions in which electrons are transferred are called electrochemical reactions. Electrochemical reactions are critical for producing countless items used in everyday life ranging from metal to food. Accurately monitoring the rate of these reactions is critical to ensure products are produced correctly and safely. Measuring electrochemical reactions is critical for environmental and medical monitoring as well. Electrochemical sensors are tools used to study and monitor these reactions. In medical laboratories, electrochemical sensors are commonly used for applications such as in vivo dopamine detection. In environmental monitoring, a handheld electrochemical sensor might be used to test heavy metal contamination in lake water. For such electrochemical sensors to be deployed at scale, it would be advantageous for a sensing system to be cheap, accurate, portable, and material efficient (i.e. using disposable electrodes). The focus of this work is to improve the accuracy and measurement efficiency of existing electrochemical techniques with the implementation of a novel sampling technique and nonlinear calibration functions.Results demonstrate that nonlinear calibration can improve interpolation performance, achieving approximately 16–25\% reductions in MAE and RMSE under LOBO validation, but does not consistently generalize to unseen concentration levels under LOCO validation. Hyperparameter tuning introduces a trade-off between interpolation accuracy and extrapolation capability. Furthermore, the proposed pairwise-subtraction sampling method increases feature dimensionality without increasing information content, leading to significant performance degradation, with errors increasing by up to a factor of seven due to redundancy. These findings highlight that calibration accuracy is limited by the information content of the measured signal and the collected dataset rather than model complexity or sampling density.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- thesis
- Discipline thesis:degree_discipline
- Electrical engineering
- Department dc:contributor.department
- Department of Electrical and Computer Engineering
- Grantor
- Iowa State University - Thesis & Dissertation
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Burns, Sam
- Advisor dc:contributor.advisor
-
- Kumar, Ratnesh
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Identifier URI
- https://dr.lib.iastate.edu/handle/20.500.12876/106571