Back to search

Iowa State University - Thesis & Dissertation

Toward safer PPE removal: Biomechanical analysis of contamination risk during medical gown doffing

Abstract

dc:description.abstract

Healthcare workers are at risk of self-contamination during the removal of personal protective equipment, yet limited research has examined the biomechanical mechanisms underlying contamination events or the influence of human and equipment factors on doffing safety. This dissertation aimed to develop and apply a kinematic assessment framework to quantify upper-limb movements, gown–hand interactions, and contamination outcomes during medical gown doffing, with a focus on sensor validation, methodological development, and experimental investigation of fatigue and gown fit.A meta-analysis first verified that inertial measurement units (IMUs) show good validity for most upper-extremity range-of-motion measurements when compared to optical motion capture, supporting their use in complex doffing tasks. An integrated IMU- and marker-based platform was then developed to measure joint kinematics, gown deformation, and finger-to-gown proximity, demonstrating that selected kinematic variables can predict contamination risk. Experimental evidence further revealed that physical fatigue significantly increased contamination events and reduced movement smoothness, indicating diminished motor control despite adherence to standardized doffing procedures. A second experimental study showed that improper gown tightness, whether excessively tight or oversized, significantly elevated contamination counts and altered movement patterns through different mechanisms, providing quantitative justification for customized gown sizing rather than a one-size-fits-all model. Overall, this dissertation demonstrates that contamination risk is influenced not only by procedural adherence but also by motor control efficiency, physical fatigue, and PPE fit. Findings provide a scientific foundation for improved PPE design, individualized sizing, ergonomics-based training, and the future development of sensor-enabled feedback systems to enhance the safety of healthcare workers.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Biomechanics
Department dc:contributor.department
Department of Kinesiology
Grantor
Iowa State University - Thesis & Dissertation
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Li, Jinfeng
Advisors dc:contributor.advisor
  • Gillette, Jason
  • Chou, Li-Shan

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Li, Jinfeng. Toward safer PPE removal: Biomechanical analysis of contamination risk during medical gown doffing. dissertation thesis, Iowa State University - Thesis & Dissertation, 2026. https://doi.org/10.31274/td-20260804-127