Back to search

Iowa State University - Thesis & Dissertation

Experimental Investigations on Various Anti-/De-Icing Methods for Ensured Aircraft Flight Safety

Abstract

dc:description.abstract

Aviation is ubiquitous in modern society, enabling international travel, commerce, diplomacy, scientific research, and many other areas of necessity. The safety of aviation is dependent not simply on pilots and ground crew, but on the engineers responsible for designing all the aircraft’s systems. Supercooled droplet icing, ice crystal icing, and mixed phase icing all constitute threats to aviation safety. Supercooled droplet icing occurs when clouds of water droplets in below-freezing atmospheric conditions impinge onto the cold surfaces of aircraft, such as wings and control surfaces, and freeze into ice. The accumulated ice may significantly increase drag and decrease lift, causing loss of performance or crashes. Ice crystal icing occurs when ice crystals impinge onto the warm surfaces of aircraft jet engines, such as inlet guide vanes and compressor blades. The ice crystals melt on impingement, whereupon heat is drawn from the substrate due to the phase change, and an ice-water slurry forms on the substrate. Over time, impinging ice crystals stick to the slurry, which eventually refreezes, and then may shed into the jet engine, causing damage and power loss. Mixed phase icing occurs in regimes where both ice crystals and supercooled droplets exist, and can affect both cold and warm surfaces. In this thesis, a series of five studies are conducted to address aviation safety in icing conditions. Firstly, an experimental investigation is carried out to characterize the relative performance of pulsed and continuous electrothermal surface heating for aircraft anti-/de-icing. High-speed imaging is employed to characterize the ice formation and runback behavior of the anti-/de-icing processes, while heat flux sensors and thermocouples are employed to quantitatively characterize the unsteady multiphase heat transfer phenomena inherent in continuous and pulsed anti-/de-icing operations. Pulsed heating is found to provide superior performance in both anti-icing and de-icing, with runback refreezing further rearwards from the leading edge in anti-icing tests, and faster times to ice-shedding events and ice-free conditions in de-icing tests. Second, a study was conducted in which biphilic coatings, surfaces consisting of alternating patterns of hydrophobic and hydrophilic coatings, are employed to improve heat transfer in an aircraft hybrid anti-/de-icing context as compared to a superhydrophobic-only hybrid method. Initial results suggest that a biphilic pattern consisting of 2 mm wide alternating strips oriented in the chordwise direction are most effective in removing built-up ice in conjunction with surface heating. Third, an experimental investigation is carried out to examine the dynamic evaporative runback process of a water droplet over a heated surface under icing conditions in relation to the surface contact angle and surface temperature. A droplet is placed on a heated surface in a wind tunnel and the freestream accelerated to 12 m/s. The film thickness and volume of the droplet are measured dynamically using digital image projection, and the heat transfer behaviour is examined using infrared imaging. It is found that lower contact angles and greater surface temperatures increase the rate of evaporation of the water film. Fourth, a study is conducted to examine the impingement behavior of ice crystals on a typical airfoil surface with varying surface temperatures and flow conditions while also characterizing the transient surface temperature development in the process. Fifth, a study is carried out using a heated, aluminum skinned airfoil in mixed phase icing conditions. Unheated icing shows large leading edge ice growth and interaction between the release and absorption of latent heat due to freezing and melting. Higher initial temperatures show less ice growth and near net zero leading edge heat flux due to the presence of a thermally unsteady interfacial layer, with full ice shedding at an initial leading edge temperature of 5.0 ⁰C. A lower liquid water fraction at an initial leading edge temperature at 0.0 ⁰C shows thinner ice and more runback with melt dominated heat transfer, while a higher liquid water fraction shows more ice accretion, less runback, and freeze-dominated heat transfer behavior.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Aerospace engineering
Grantor
Iowa State University - Thesis & Dissertation
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Digavalli, Kiran, Boyer
Advisor dc:contributor.advisor
  • Hu, Hui

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Digavalli, Kiran, Boyer. Experimental Investigations on Various Anti-/De-Icing Methods for Ensured Aircraft Flight Safety. dissertation thesis, Iowa State University - Thesis & Dissertation, 2026. https://doi.org/10.31274/td-20261111-179