Back to search

Iowa State University

Ionic liquids: MALDI-MS matrices and gas chromatography stationary phases

Abstract

dc:description.abstract

<p>This thesis shows the systematic variation of both the cation and anion to find an ionic liquid matrix that produces the greatest analyte S/N ratio. It is also demonstrated that these new ILMs have a greater mass detection range and can be used for a wider variety of analytes. Analytes tested include peptides, proteins, and carbohydrates.</p> <p>Also reported is the characterization of sixteen biodegradable polymers with two ILMs and five solid matrices. It is shown that the ILM produces less degradation and typically allows detection of an almost Gaussian distribution of analyte peaks. This allows detection of a more accurate and precise number average molecular weight and weight average molecular weight.</p> <p>It is also shown that the use of an ionic liquid stationary phase as the secondary column, in 2D-GC, for the separation of volatile organic compounds and 13 chemical markers found in the headspace of US currency. Tthe use of 2D-GC in the stop flow operation mode is also shown.</p> <p>It is also shows the separation of phosphorus-oxygen (P-O) containing compounds from a complex mixture using a triflate ionic liquid column as the secondary column in 2D-GC. These phosphorus-oxygen containing compounds are chemical warfare agent simulants. The separation of the P-O containing compounds on the triflate ionic liquid and the commercial DB-WAX (polyethylene glycol) columns are compared. It was found that the triflate IL column was much more selective for the P-O containing compounds than was the DB-WAX column.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Crank, Jeffrey
Advisors dc:contributor.advisor
  • Daniel W. Armstrong
  • Victor S. Lin

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/10615/
Dc Identifier Other
1593
2806760
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/10615/Crank_iastate_0097E_10453.pdf|||Fri Jan 14 18:24:52 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Crank, Jeffrey. Ionic liquids: MALDI-MS matrices and gas chromatography stationary phases. dissertation thesis, 2009. https://doi.org/10.31274/etd-180810-1080