Back to search

Iowa State University

Design of joints for laterally loaded UHPC columns

Abstract

dc:description.abstract

<p>This study focuses on the use of Ultra-High Performance Concrete (UHPC) on seismic applications. As part of this effort, UHPC members have been tested for the first time under non-emulative connections for resisting seismic type lateral loads. Due to the limited compression strain of UHPC, identifying a suitable soft interface material at the member end was the main objective in order to accommodate large compression strain demand so that the UHPC members can be subjected to large lateral displacements.</p> <p>Three precast unbounded post-tensioned UHPC columns were experimentally and analytically investigated using three different interface materials. They were Hydrostone, steel fiber grout and glass fiber epoxy pad along with easily replaceable external steel angles as energy dissipaters. Through this investigation, it was intended to establish a precast UHPC column connection with replaceable external energy dissipater and adequately deformable member end interface as these features enable the UHPC columns to be used in seismic applications. Before testing, a finite element model was developed to predict the lateral load behavior of the test columns, using all known UHPC properties and assumed interface material properties. To study the influence of the pad on the system, the UHPC columns were first tested for few cycles only with the pad. In addition to repeating these cycles, they were tested under large lateral displacements after the external energy dissipaters had been added. As the tests were conducted, samples from the interface materials were collected and tested separately for obtaining compressive stress-strain envelopes, which were later used in the finite element model to improve the analysis results.</p> <p>Based on the research results, it was found that the Glass fiber epoxy performed better than other interface materials and the analytically calculated load versus displacement responses closely matched with the responses of all the experimental results. It was also found from the analysis that use of hollow UHPC columns may be adequate as this would lead to cost-effective design.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Department dc:contributor.department
Department of Civil, Construction and Environmental Engineering
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Srinivas Murthy, Rakesh
Advisor dc:contributor.advisor
  • Sri Sritharan

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/11076/
Dc Identifier Other
2137
2807335
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/11076/SrinivasMurthy_iastate_0097M_10898.pdf|||Fri Jan 14 18:41:37 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Srinivas Murthy, Rakesh. Design of joints for laterally loaded UHPC columns. thesis thesis, 2009. https://doi.org/10.31274/etd-180810-1358