Pretest 3-D finite element analysis of the girder-to-cap-beam connection of an inverted-tee cap beam designed for seismic loadings

Abstract

dc:description.abstract

<p>This thesis provides a pretest analysis of a commonly used and increasingly popular superstructure-to-cap-beam connection used in the state of California subjected to seismic loading. The current connection investigated is used for precast girders placed on inverted-tee cap beams. The development of a prototype bridge and a 50% scale test unit was discussed. Then multiple models were analyzed ranging from a single girder with a cap beam to a assembly with a column, cap beam, diaphragms, deck slab and ten girders based on the prototype and test unit. The analysis models were analyzed in the general purpose finite element program ABAQUS. A new connection detail utilizing an unstressed, prestressing strand placed through the girders was then modeled and proposed to provide a moment resistant connection and allow a plastic hinge to form in the top of the column. By allowing a plastic hinge to form in the top of the column the system is more economical then the current design detail.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Department dc:contributor.department
Department of Civil, Construction and Environmental Engineering
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thiemann, Zachary
Advisor dc:contributor.advisor
  • Sri Sritharan

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/11100/
Dc Identifier Other
2133
2807331
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/11100/Thiemann_iastate_0097M_10921.pdf|||Fri Jan 14 18:42:44 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Thiemann, Zachary. Pretest 3-D finite element analysis of the girder-to-cap-beam connection of an inverted-tee cap beam designed for seismic loadings. thesis thesis, 2009. https://doi.org/10.31274/etd-180810-1090