Back to search

Iowa State University

Laser texturing of drug eluting stents to improve drug adhesion

Abstract

dc:description.abstract

<p>Drug eluting stents have made significant advances in reducing restenosis over bare metal stents; however, further research is required to decrease the likelihood of late stent thrombosis. Thrombosis is often caused by hypersensitivity to the stent, the polymer, and the drug. This study investigates the potential to eliminate the polymer on drug eluting stents to decrease the chance of the requirement of a second procedure to reopen the artery. Nanosecond laser texturing of metallic stent surfaces generates laser-induced periodic surface structures, also referred to as ripples, which can be utilized to promote drug adherence directly to the stent surface. Surface profilometer results demonstrated that laser texturing significantly improves surface topography over bare metal stents. With a 488% increase in volume per unit area, laser texturing dramatically increased the volume of drug that can be contained in the valleys of the stent surface. In addition, the mean valley slope was improved by 420%, indicating that the aspect ratio of the valleys is significantly higher resulting in a higher resistance to erosion of the drug by the flow of blood during stent placement. Drug elution trials proved that laser texturing of metallic stents offers steadier release rates and better drug adhesion than biodegradable polymer stents. Since drug elution tests are expensive to carry out to determine conditions that will yield the desired release rate, an analysis is made using the weighted property index method and the following surface characteristics: surface area ratio, surface roughness, volume of lubricant per unit area from the bearing ratio analysis, and mean valley slope. This study compared four speeds ranging from 0.5 to 1.25 mm/s and showed that 1.25 mm/s produced the greatest ripple formation while minimizing process time.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Department dc:contributor.department
Department of Mechanical Engineering
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Buehler, Michelle
Advisor dc:contributor.advisor
  • Pal A. Molian

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/12225/
Dc Identifier Other
3209
2808407
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/12225/Buehler_iastate_0097M_12007.pdf|||Fri Jan 14 19:16:07 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Buehler, Michelle. Laser texturing of drug eluting stents to improve drug adhesion. thesis thesis, 2011. https://doi.org/10.31274/etd-180810-2751