Relaxing the requirements for accurate spectral testing of data converters

Abstract

dc:description.abstract

<p>Analog-to-digital converters (ADCs) are becoming increasing more common to be involved in many systems in integrated circuits. One of the difficulties being faced is to be able to accurately and cost-effectively test the continually higher performance ADCs. Part of this test is being able to assess the dynamic linearity of the ADC through dynamic spectral testing. The standard test method for ADCs can be difficult to implement accurately and cost effectively due to the stringent requirements. Three different algorithms are proposed that can be used to relax the test requirements in order to reduce the cost of the test equipment while still being able to maintain the test accuracy. The accuracy and robustness of these methods will be shown through simulation and measurement results.</p> <p>The first algorithm developed is relaxing the requirements on the linearity of the test signal and of the need to achieve coherent sampling. The standard test requires that the input signal linearity be about 20dB more pure than the ADC under test along with always maintaining coherent sampling. This algorithm will reduce the purity requirement by allowing the test signal to be much less pure than the ADC under test while also completely removing the need for coherent sampling.</p> <p>The second algorithm is focusing on adding the allowance of the signal to be clipped in addition to the claims of the first algorithm. The standard test requires the input signal to be near full range of the ADC under test without clipping. This algorithm allows for the signal to be clipped up to 1% while still ensuring accurate results.</p> <p>The last algorithm is performing spectral testing of the ADC using a DAC of equal or lower linear performance. If accurate estimates of the INL/DNL of the ADC using a lower performance DAC can be obtained using other algorithms under development, then pre-distortion codes can be added to the DAC to accurately test the dynamic spectral testing performance of the ADC.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Magstadt, Benjamin
Advisor dc:contributor.advisor
  • Degang J. Chen

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/13918/
Dc Identifier Other
4925
6199637
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/13918/Magstadt_iastate_0097M_14318.pdf|||Fri Jan 14 20:04:10 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Magstadt, Benjamin. Relaxing the requirements for accurate spectral testing of data converters. thesis thesis, 2014. https://doi.org/10.31274/etd-180810-3613