Back to search

Iowa State University

Monitoring of single and multiple line outages with synchrophasors in areas of the power system

Abstract

dc:description.abstract

<p>When power grids are heavily stressed with a bulk power transfer, it is useful to have a fast indication of the increased stress when multiple line outages occur. Reducing the bulk power transfer when the</p> <p>outages are severe could forestall further cascading of the outages.</p> <p>Phasor measurement units (PMUs) are vital elements for monitoring and control of these heavily stressed power system. This work presents a new approach to implement and utilize PMU information to monitor operational transfer capability and limits based on voltage phasor angles with respect to thermal limits of transmission lines. This work demonstrates an algorithm to obtain thresholds based on the angle and then quickly deploy PMU data to monitor stress changes due to single and multiple outages in real time to send fast notification of emergency situations. Area angle uses the topology and the synchronized measurements of angles across an area of power system to measure stress caused by outages within the area. The proposed algorithm is easy, quick and computationally suitable for real systems to capture bulk stress caused by outages and also identify local stress. This work first illustrates the idea of area angle in a Japanese test system and then explores the choice of the border buses. It further investigates the relation between area angle to area susceptance and supports the findings in two areas of the Western North American power system.</p> <p>Finally, this work develops a procedure to define thresholds for the area angle that relate to the maximum power that can be transferred through the area until a line limit is reached. The algorithm finding the area angle thresholds offline and then in real time monitoring the area angle and comparing it to the thresholds after multiple outages determines the urgency (or not) of actions to reduce the bulk transfer of power through the area.</p> <p>The procedure also identifies exceptional cases in which separate actions to resolve local power distribution problems are needed.</p> <p>The findings are supported by testing on a 1553 bus reduced model of the Western interconnection power system.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Darvishi, Atena
Advisor dc:contributor.advisor
  • Ian Dobson

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/14761/
Dc Identifier Other
5768
8329532
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/14761/Darvishi_iastate_0097E_15224.pdf|||Fri Jan 14 20:26:07 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Darvishi, Atena. Monitoring of single and multiple line outages with synchrophasors in areas of the power system. dissertation thesis, 2015. https://doi.org/10.31274/etd-180810-4347