Micro-cantilever based biosensor for electrical actuation and detecting molecular interactions

Abstract

dc:description.abstract

<p>Biosensors that are based on Atomic force microscope (AFM) cantilevers have recently been attracting interest and attention because of its portability and high sensitivity, the gold coated cantilever surface enable researchers to functionalize the cantilever by immobilizing biomolecules like enzyme, DNA, RNA. Reactions between the immobilized molecules and its target molecules on the cantilever can lead to change in measurable signal (e.g. deflection, resonant frequency). By measuring the deflections or resonant frequency change, researchers are able to detect the presence and quantity of target molecules. This property of AFM cantilever allows itself to have potential application in DNA/Protein detection.</p> <p>We designed an optical system to monitor the deflection of cantilever subjected to electrochemical stimuli in solution. The cantilever was used as the working electrode of a three-electrode cell in order to add an electrical potential onto the functionalized cantilevers for an external stimuli. In my three experiments, Cantilevers with different functionalized surfaces were tested under positive and negative electrical potentials. Several conclusions were obtained based on the measured cantilever deflection. First, immobilized thrombin aptamer can result in a compressive surface stress (compare to gold cantilever coated with alkanethiol) on gold coated cantilever when negative voltage was applied, and a tensile surface stress when positive voltage was applied. Secondly, different molecules immobilized on gold coated cantilever can lead to different deflections under square wave of -100mV and +100mV voltage. The conformational change of thrombin aptamer caused extra compressive surface stress under -100mV and extra tensile surface stress under +100mV. Also the thrombin molecules that bind with aptamers may inhibit the conformational change of aptamer under electrical potential. Because the adenine base pair on poly A does not form a structure like the G-quadruplex form of thrombin aptamer molecules, the poly A immobilized cantilever does not have deflection change as large as thrombin aptamer cantilever under electrical potential. Thirdly, at concentrations lower than 0.1nM, the deflection of aptamer functionalized cantilever under electrical field decays rapidly as the concentration increases. This phenomenon may have potential application in detecting extremely low thrombin concentration.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Department of Mechanical Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhu, Zhichen
Advisor dc:contributor.advisor
  • Pranav Shrotriya

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/15190/
Dc Identifier Other
6197
8943297
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/15190/Zhu_iastate_0097M_15589.pdf|||Fri Jan 14 20:37:00 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Zhu, Zhichen. Micro-cantilever based biosensor for electrical actuation and detecting molecular interactions. thesis thesis, 2016. https://doi.org/10.31274/etd-180810-4793