Back to search

Iowa State University

Estimation of physical activity intensity using triaxial ActiGraph accelerometers in youth populations: Impact of data type, attachment site, and modeling approach, including adaptations of the Sojourn method for varied use in youth

Abstract

dc:description.abstract

<p>Adequate physical activity (PA) in youth is essential for short- and long-term health. However, it is difficult to perform large-scale assessments of youth PA levels and be assured of accurate results. Recent developments in accelerometer-based PA monitoring for adults (e.g. the Sojourn method) have enhanced the accuracy attainable by those devices, but the same has not been accomplished for youth. PURPOSE: The purpose of this study was to develop and cross-validate versions of the established Sojourn method that can be used for research with youth. METHODS: The study involved two phases. In Phase 1, existing ActiGraph monitor data from 54 youth were used to train artificial neural networks that were implanted into customized shells of the existing Sojourn method, and these were compared against indirect calorimetry for validation. In Phase 2, a separate cross validation analysis was conducted on an independent sample of 21 youth that wore Actigraph monitors during a simulated free-living protocol. This phase utilized direct observation as the criterion measure of activity intensity and consisted of one hour of self-directed activity, with limited direction provided outside of the requirement that at least 5 activities be performed within the hour. In both phases, standard processing methods were included to compare the relative utility of the new methods to the established and currently available techniques for both hip and wrist ActiGraph data. Phase 2 additionally compared non-dominant and dominant wrist attachment. Tests of classification accuracy (confusion matrices, sensitivity and specificity, percent accuracy, and kappa statistics) were used in both phases to evaluate the methods. RESULTS: The adapted Sojourn methods achieved accuracies ranging from 53.9% to 73.7% in Phase 1 (kappa scores from 0.24 to 0.44). In Phase 2, the adaptations fell between 38.2% and 60.5% accuracy (kappa scores from 0.06 to 0.41). The adapted Sojourn method using activity counts from hip worn Actigraph monitor showed the strongest overall performance. CONCLUSIONS: The adaptations of the Sojourn method were more accurate than currently available methods for youth, but improvements are still needed, particularly for methods using raw acceleration data from the wrist. Attachment to the dominant or non-dominant wrist is inconsequential.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Kinesiology
Department dc:contributor.department
Department of Kinesiology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hibbing, Paul
Advisor dc:contributor.advisor
  • Greg Welk

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/15718/
Dc Identifier Other
6725
11165085
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/15718/Hibbing_iastate_0097M_15913.pdf|||Fri Jan 14 20:45:36 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hibbing, Paul. Estimation of physical activity intensity using triaxial ActiGraph accelerometers in youth populations: Impact of data type, attachment site, and modeling approach, including adaptations of the Sojourn method for varied use in youth. thesis thesis, 2016. https://doi.org/10.31274/etd-180810-5346