In-tube evaporation and condensation heat transfer of refrigerant mixtures
Abstract
dc:description.abstractThe purpose of this study was to evaluate five different HFC refrigerants which are potential replacements for the chlorine-based refrigerants, which are R-22 and R-502. Heat transfer coefficient data were taken during in-tube evaporation and condensation of refrigerant mixtures in a 9.5 mm (3/8") O.D. smooth copper tube. The data were taken at temperatures of -2.0°C and 4.0°C for evaporation and 30°C and 40°C for condensation. Three nonazeotropic refrigerant mixtures and R-125 were tested and compared against baseline data for R-22. One non-azeotropic refrigerant mixture was tested and compared against baseline data for R-502. Four different mass fluxes ranging from 125 to 375 kg/s-m² were tested. On a mass basis, the mixtures tested and compared against R-22 were: R-134a(75%) / R-32 (25%) R-134a (90%) / R-32 (10%) R-32 (30%) / R-125 (10%) / R-134a (60%) The mixture tested and compared against R-502 was R-404A which has mass components of: R-125 (44%) / R-143a (52%) / R-134a (4%) When the R-22 substitute refrigerants were compared for evaporation on an equal mass flux basis, the performances ranged from 12% less than R-22 to 7% larger than R-22. The mixture R-32 (30%) / R-125 (10%) / R-134a (60%) performed the best while R-32(10%) / R134a(90%) performed the worst. The pressure drops measured ranged from half that of R-22 to 1.3 times that of R-22. During condensation, none of the refrigerant mixtures evaluated had heat transfer coefficients higher than R-22. During evaporation for the R-502 substitute, namely R-404A, the heat transfer coefficient was 23% higher and the pressure drop was 2.8% lower for a mass flux of 300 kg/s-m² and a temperature of 4°C compared to R-502. When compared on an equal cooling capacity basis, during evaporation, R-404A had a heat transfer coefficient 21% higher than R-502 at 4.0 °C and 45 kW/m². For condensation the mixture had a heat transfer coefficient 3% higher than R-502 for a temperature of 40 °C. When compared on an equal heating capacity basis during condensation, R-404A had a heat transfer coefficient 6% larger than R-502 at 30 °C and 30 kW/m².
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department thesis:degree_department
- Department of Mechanical Engineering
- Year dc:date.issued
- 1997
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Doerr, Thomas Michael
- Advisor dc:contributor.advisor
-
- Pate, Michael B.
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://dr.lib.iastate.edu/handle/20.500.12876/2vaZDB8r