Back to search

Iowa State University

Monitoring voltage stability margin across several transmission lines using synchrophasor measurements

Abstract

dc:description.abstract

<p>Power systems are frequently exposed to large transfers of power between areas, which can increase the risk of voltage stability problems and blackout. In addition, multiple outages are more likely to occur during severe weather and cyber physical attacks, which can weaken the power system and also increase the risk of voltage stability problems and blackout. To address these problems, it is desirable to be able to quickly monitor voltage stability online for corridors vulnerable to voltage stability problems. It is useful to do this monitoring without running simulation or estimate the state because power systems are very complex and there is not enough time for running simulation for all the possible multiple outages, and the state estimator may not converge for some severe outages.</p> <p>This thesis proposes two new methodologies for a fast online evaluation of voltage stability margin across several transmission lines and under multiple contingencies. The first methodology is based on the voltage across area reduction, and the second is based on the preservation of the complex power of the transmission corridor. Those methods are based on synchrophasor measurements, giving the operators a fast indication of voltage stability problems that is independent of state estimation. In addition, this thesis proposes a new voltage stability index that is tracking the maximum power that the corridor with multiple lines can transfer.</p> <p>Current methods of voltage stability monitoring with syncrhophasor measurements work for a load supplied by a corridor with a radial single line. However, many practical situations involve load supplied by more complicated corridors with multiple transmission lines. Thus, this thesis shows how to reduce multiple corridors to a closely equivalent radial corridor, including the variation of all loads that are connected to the corridor. The monitoring method can easily accommodate changes in the generator reactive limits. Furthermore, we tested these methods with satisfactory results in several systems, including a real power system, and compared it with commercial software, obtaining excellent results.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ramirez Arbelaez, Lina
Advisor dc:contributor.advisor
  • Ian Dobson

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/15999/
Dc Identifier Other
7006
11169510
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/15999/RamirezArbelaez_iastate_0097E_16105.pdf|||Fri Jan 14 20:49:40 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ramirez Arbelaez, Lina. Monitoring voltage stability margin across several transmission lines using synchrophasor measurements. dissertation thesis, 2016. https://doi.org/10.31274/etd-180810-5626