Back to search

Iowa State University

Analysis of high temperature effects on piezoelectric based ultrasonic transducers

Abstract

dc:description.abstract

<p>Under sodium viewing (USV) using ultrasonic pulse-echo techniques offers the potential for the inspection of generation IV, liquid sodium-cooled fast reactors (SFRs) at the hot stand-by temperature (260C). However, the harsh environment effects on the transducer reduce the ultrasonic signal strength which also limits the probability of detection (POD) of the defects.</p> <p>Current work presents a unified modeling and measurement-based methodology to analyze the high temperature effects on the transducer components. Resonance analysis-based characterization has shown that the conventional d33 piezoelectric parameter is not a sufficient condition to estimate resonance characteristics of high temperature ultrasonic transducers. A full piezoelectric material matrix needs to be utilized in order to estimate high temperature performance. In seeking materials, BiScO3-PbTiO3 (Bismuth Scandium oxide-lead titanate) is demonstrated to be the piezoelectric material that could potentially be used for hot stand-by mode (260C) inspection of SFRs.</p> <p>However, a high temperature ultrasonic transducer is also a multi-layer system where the interaction of multiple acoustic layers is equally important as the temperature dependence of a single piezoelectric layer. A 3-layer problem was studied which demonstrated the thermal cycling effect on the interfaces, evident from the echo amplitudes and bandwidth of the frequency response up to 260C. A unique bi-modal resonance phenomenon was also found in the transducer due to interaction of the multiple acoustic layers.</p> <p>Utilizing these insights, design, development and high temperature evaluation of several prototypes was performed in surrogate fluids. This resulted in an air-backed transducer using BS-PT piezoelectric material, nickel faceplate, and liquid acoustic coupling with silicone oil. The transducer demonstrated the ability for imaging regions of different thickness within the specimen, critical for USV capabilities in SFRs.</p> <p>Current work also developed a cost effective, novel temperature compensated transfer function approach to predict POD at high temperature using room temperature experimental data. Such a model-assisted POD approach quantified effect of temperature dependence of PZT-5A material on POD near 200C. This approach could be extended for other high temperature transducer materials using a physics based-model and room temperature experimental data to estimate high temperature POD.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Engineering Mechanics
Department dc:contributor.department
Department of Aerospace Engineering
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bilgunde, Prathamesh
Advisor dc:contributor.advisor
  • Leonard J. Bond

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/16317/
Dc Identifier Other
7324
12318405
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/16317/Bilgunde_iastate_0097E_17350.pdf|||Fri Jan 14 20:58:25 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Bilgunde, Prathamesh. Analysis of high temperature effects on piezoelectric based ultrasonic transducers. dissertation thesis, 2018. https://doi.org/10.31274/etd-180810-5947