Back to search

Iowa State University

Ultra-fast Alternating Current Potential Drop Measurement System for Materials Characterization and Precision Impedance Analyzer for Eddy Current Measurement

Abstract

dc:description.abstract

<p>The alternating current potential drop method (ACPD) with four-point probe injects alternating current into the sample under test from the two outer drive pins and measures the voltage (potential) drop between the two inner pick-pins. This method can be used to measure electrical conductivity, linear permeability, coating depth, as well as crack size. However, the measurement speed and accuracy of present ACPD system need to be dramatically improved.</p> <p>This work discusses the design, implementation and test of a novel ultra-fast standalone ACPD system. New and powerful hardware including high current transconductance amplifier and low noise amplifier provide a sound foundation for nearly perfect system level noise performance; new time domain to frequency domain conversion method increases the measurement speed without sacrificing noise performance. A general purpose calibration method is introduced so that the accuracy of this system is guaranteed.</p> <p>With the development and introduction of this new ACPD instrument, ACPD method has evolved from a laboratory NDE method to a full blown technique that is ready for real world application.</p> <p>The last chapter of this thesis discusses a simple but powerful lock-in amplifier based precision impedance analyzer. This impedance analyzer provides an economical solution to eddy current testing that requires highest precision.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ji, Yuan
Advisor dc:contributor.advisor
  • John R. Bowler

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/16759/
Dc Identifier Other
7766
13580115
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/16759/Ji_iastate_0097E_16148.pdf|||Fri Jan 14 21:05:33 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ji, Yuan. Ultra-fast Alternating Current Potential Drop Measurement System for Materials Characterization and Precision Impedance Analyzer for Eddy Current Measurement. dissertation thesis, 2016. https://dr.lib.iastate.edu/handle/20.500.12876/30942