Iowa State University
High voltage quinone flow battery with hybrid acid and base electrolytes
Abstract
dc:description.abstract<p>Performance of an all quinone redox flow battery is enhanced via using electrolytes with</p> <p>contrasting pH on both sides of the proton exchange membrane. This performance increase</p> <p>includes elevation of the open circuit voltage by 300 mV to 1.5 V at SOC of 50% and augmentation</p> <p>of energy density by a factor of three to 20.6 Wh/Kg in reference to the previous redox flow battery</p> <p>developed earlier. The battery is able to operate at current densities up to 80 mA/cm2 and meeting</p> <p>columbic efficiency of 99.9% and energy density of 70%. Moreover, the battery with contrasting</p> <p>pH was able to operate for more than 140 hours continuously. Final system pH was similar to the</p> <p>initial system pH. Furthermore, durability of the referenced flow battery is enhanced by using this</p> <p>technique via maintaining a neutral pH on the cathode side of the flow battery comprising of</p> <p>Dihydroxy Anthraquinone and ferricyanide ion.</p> <p>Electrolyte pH might affect redox reaction of the analytes significantly. For example, redox</p> <p>potential of quinone compounds that entail protonation step in their electrochemical reaction might</p> <p>change by pH and some compounds such ferricyanide ion or TEMPO compounds might not be</p> <p>able to demonstrate reversible reactions at a specific pH. Capability of manipulation of the pH of</p> <p>each half cell independently from the other half cell can bring various advantages such as coupling</p> <p>half reactions that operate at completely different pH and affect redox potential, durability or</p> <p>energy density accordingly and such applications might even transcend the boundaries of the redox</p> <p>flow batteries.</p> <p>Half-cell characteristics of the catholyte such as redox potential, reversibility, stability and</p> <p>kinetics have been analyzed in this work while the similar aspects of the anolyte have been</p> <p>analyzed in literature. Single-cell tests for both systems have been performed and the results as</p> <p>well as the test conditions and methods are displayed. The systems include the DHAQ (pH=14)</p> <p>vs Ferricyanide ion (pH= 7) redox flow battery that is discussed in chapter 3 as well as DHAQ</p> <p>(pH=14) vs HQDS (pH=0.3) (hydroquinone disulfonic acid) flow battery that is discussed in</p> <p>chapter 4.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- thesis
- Discipline thesis:degree_discipline
- Chemical Engineering
- Department dc:contributor.department
- Department of Chemical and Biological Engineering
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Torabi, Mohsen
- Advisor dc:contributor.advisor
-
- Wenzhen Li
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier
- archive/lib.dr.iastate.edu/etd/17337/
- Dc Identifier Other
-
8344
15016723 - Mods Identifier Filename
- archive/lib.dr.iastate.edu/etd/17337/Torabi_iastate_0097M_18015.pdf|||Fri Jan 14 21:20:50 UTC 2022