Back to search

Iowa State University

Precision Measurements of Blazar Spectra with VERITAS

Abstract

dc:description.abstract

<p>Imaging-Atmospheric Cherenkov Telescopes (IACTs) provide insights into a number of open questions in high energy physics, astroparticle physics, and cosmology. However, due to the indirect detection methods necessary to observe TeV gamma rays, the systematic and statistical errors produce a broad energy resolution of about 15--20\% during analysis. Therefore, investigating and characterizing systematics of IACTs is necessary for producing accurate measurements. This thesis presents an analysis technique developed to characterize VERITAS systematics at TeV energies on blazar spectra arising from saturation of the electronics. The application of this analysis method to two epochs of data from the Crab Nebula, extending above 20\ TeV, determined minimal systematic effects from saturation. Instead, the analysis showed bias arising primarily from the choice of low gain ratio, which lead to further investigation of the correct value to apply for the low gain ratio during analysis. With correct values of the low gain ratio applied, the systematic bias from saturation of the electronics is less than statistical errors out to energies greater than 20\ TeV. Finally, analysis of five blazar spectra extending to multi-TeV energies is presented, with both the nominal low gain ratios and the low gain ratios as determined in this thesis. The updated low gain ratio values demonstrate improved energy reconstruction in a VERITAS analysis, leading to more precise spectral reconstruction with low systematic bias from saturation of the electronics.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Astrophysics
Department dc:contributor.department
Department of Physics and Astronomy
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wells, Rita
Advisor dc:contributor.advisor
  • Frank Krennrich

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/17606/
Dc Identifier Other
8613
15681651
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/17606/Wells_iastate_0097E_18342.pdf|||Fri Jan 14 21:26:19 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Wells, Rita. Precision Measurements of Blazar Spectra with VERITAS. dissertation thesis, 2019. https://dr.lib.iastate.edu/handle/20.500.12876/31789