AC/DC differential bridge based solution-electrode interfacial capacitance biosensor, for field-deployable real-time and low-cost detection of MCLR in drinking water.

Abstract

dc:description.abstract

<p>Microcystin-LR (MCLR, one of the most toxic and commonly found products of cyanobacteria in freshwater resources, threatens human health and the livestock. WHO has set a standard limit of 1 μg⁄l for the concentration of MCLR in drinking water. The lab-based, specialized water quality monitoring tests for this purpose are not only expensive but also slow and require sample preparation and transportation from distant sites. Therefore, there is a need for a handheld, field-deployable and low-cost biosensor to make frequent water quality monitoring easier.</p> <p>Many field-deployable biosensors with applications in environmental monitoring and healthcare where concentrations of interest are on the order of μg/l and fewer face challenges in achieving high dynamic range and lower detection resolution due to the resultant small fractional change in the transducer characteristics. Additionally, non-faradaic label-free biosensors for MCLR type applications face difficulty in real-time data analysis due to signal drift, non-specific binding of non-target particles and last but not least noise coming from both transducer and readout electronics.</p> <p>This dissertation is mainly focused on utilizing electronic circuit methods to fill the gap of reading small responses from the bio-transducer with sufficient accuracy and sensitivity. Differential bridge based transduction as sensitivity booster and careful design of amplification unit and real-time signal processing capable of extracting signal information buried in noise are part of the presented work that achieves 8-bit resolution within a 1% full-scale transducer fractional capacitive change.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Neshani, Sara
Advisor dc:contributor.advisor
  • Nathan M. Neihart

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/etd/17756/
Dc Identifier Other
8763
16525085
Mods Identifier Filename
archive/lib.dr.iastate.edu/etd/17756/Neshani_iastate_0097E_18569.pdf|||Fri Jan 14 21:28:32 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Neshani, Sara. AC/DC differential bridge based solution-electrode interfacial capacitance biosensor, for field-deployable real-time and low-cost detection of MCLR in drinking water.. dissertation thesis, 2019. https://dr.lib.iastate.edu/handle/20.500.12876/31939