Back to search

Iowa State University

In-tube evaporation and condensation of HFC-134a and CFC-12 with various lubricant mixtures

Abstract

dc:description.abstract

<p>Mandates currently in place by the Environmental Protection Agency require use of new environmentally acceptable refrigerants by 1996. Implementation of these new refrigerants by refrigeration and air-conditioning manufactures requires design data for the various components of these systems. This study focused on obtaining design data for evaporators and condensers of vapor compression systems. Specifically, a new environmentally acceptable refrigerant HFC-134a, which is targeted as a replacement for refrigerant CFC-12, was tested in an instrumented evaporator and condenser and their performance measured;Heat transfer coefficients and pressure drops were measured during evaporation and condensation of HFC-134a and CFC-12 in smooth and micro-fin tubes. Two different diameter smooth tubes and micro-fin tubes were tested: 9.52-mm outside diameter tubes and 12.7-mm outside diameter tubes. Micro-fin tubes are characterized by the numerous small fins that spiral down the inner surface of the tube. The micro-fin tubes used in this study had 60 fins with a spiral angle of 17° and fin heights of 0.2 mm. The heat transfer coefficients and pressure drops measured in this study were averages over the 3.66-m long test tubes. The refrigerant mass flux was varied from 125 kg/m[superscript]2·s to 375 kg/m[superscript]2·s in both the smooth and micro-fin tubes;The experimental data showed a significant increase in the performance of HFC-134a in the micro-fin tube as compared to the smooth tube. Specifically, evaporation heat transfer coefficients were increased by 50% to 100% with only a 10% to 30% increase in evaporation pressure drop, while condensation heat transfer coefficients were increased by 100% to 200% with a 40% to 100% increase in condensation pressure drop. Similar results were obtained for pure CFC-12 in the micro-fin tube;The effects of lubricant concentration (\prec5%) on the performance of HFC-134a and CFC-12 were also studied. HFC-134a was tested with a penta erythritol ester mixed-acid lubricant and a penta erythritol ester branched-acid lubricant. CFC-12 was tested with a naphthenic lubricant. Lubricant concentration in general decreased the heat transfer performance of refrigerants. The only exception was evaporation at low lubricant concentrations were the heat transfer coefficients were slightly enhanced by refrigerant/lubricant mixtures. Pressure drop during evaporation and condensation was increased by the addition of lubricant in most cases.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Mechanical Engineering
Year dc:date.issued
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Eckels, Steven
Advisor dc:contributor.advisor
  • Michael B. Pate

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/10228/
Dc Identifier Other
11227
6386179
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/10228/r_9334977.pdf|||Fri Jan 14 18:16:38 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Eckels, Steven. In-tube evaporation and condensation of HFC-134a and CFC-12 with various lubricant mixtures. dissertation thesis, 1993. https://doi.org/10.31274/rtd-180813-11226