Back to search

Iowa State University

Effect of various mixing devices and patterns on flocculation kinetics in water treatment

Abstract

dc:description.abstract

<p>This research was designed to investigate the effects of different mixing variables on flocculation kinetics of kaolinite clay suspension at both warm and cold water temperatures (23°C and 5°C) using alum and ferric nitrate under a number of physico-chemical conditions. The following work was performed during this experimental study: (1) G versus rpm curves for different impellers were developed using calculated power based on measured torque. The torque was measured by a rotating torque meter using a photographic technique. (2) The effects of impeller geometry, rapid mixing intensity and pattern, concentration of coagulant dosing solution, coagulant injection pattern, and slow mixing intensity and pattern on flocculation efficiency were investigated in a bench scale batch reactor at both warm and cold water temperatures with metal coagulants;All the experiments were performed in a batch reactor with 18-L liquid working volume inside a walk-in constant temperature room using five impeller geometries. The primary particles were kaolinite and they were flocculated using alum and ferric nitrate (Fe(NO[subscript]3)[subscript]3.9 H[subscript]2 O].;The paddle type mesh impeller performed significantly better than the turbine type impellers (2-blade and A 310) under all conditions tested. All the paddle type impellers (mesh, modified stake, and 2-blade stack) performed almost identically under the conditions tested. Both rapid mixing intensity and pattern had a remarkable impact on flocculation kinetics. An optimum G-value was obtained for each set of conditions. The low intensity, longer duration, rapid mix pattern outperformed the high intensity, short duration, rapid mix pattern in almost all the conditions studied;Slow injection, dilute dosing solution and multi port injection proved more beneficial than the pulse injection, concentrated dosing solution, and the single port injection respectively. There was an optimum slow mix G for each set of experimental conditions when constant G-slow mixing was adopted. Reducing the slow mix G as flocculation progressed resulted in higher flocculation index as flocculation progressed and better settled water turbidity due to less danger of floc breakup. All the mixing variables tested in this study demonstrated a more pronounced effect on flocculation kinetics at cold temperature than at warm temperature.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Civil, Construction and Environmental Engineering
Year dc:date.issued
1995

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sajjad, Md.
Advisor dc:contributor.advisor
  • John L. Cleasby

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/10717/
Dc Identifier Other
11716
6415882
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/10717/r_9531783.pdf|||Fri Jan 14 18:26:56 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Sajjad, Md.. Effect of various mixing devices and patterns on flocculation kinetics in water treatment. dissertation thesis, 1995. https://doi.org/10.31274/rtd-180813-12663