Back to search

Iowa State University

Inductively coupled plasma spectrometry: noise characteristics of aerosols, application of generalized standard additions method, and Mach disk as an emission source

Abstract

dc:description.abstract

<p>This dissertation is focused on three problem areas in the performance of inductively coupled plasma (ICP) source;The noise characteristics of aerosols produced by ICP nebulizers are investigated. A laser beam is scattered by aerosol and detected by a photomultiplier tube and the noise amplitude spectrum of the scattered radiation is measured by a spectrum analyzer. Discrete frequency noise in the aerosol generated by a Meinhard nebulizer or a direct injection nebulizer is primarily caused by pulsation in the liquid flow from the pump. By use of a pulse-free pump, the discrete frequency noise is eliminated. The configuration of the spray chamber affects the white noise level. A Scott-type spray chamber suppresses white noise, while a conical, straight-pass spray chamber enhances white noise, relative to the noise seen from the primary aerosol. The noise in the aerosol from a continuous-flow ultrasonic nebulizer has a relatively high 1/f component;Simultaneous correction for both spectral interferences and matrix effects in ICP atomic emission spectrometry (AES) can be accomplished by using the generalized standard additions method (GSAM). Results obtained with the application of the GSAM to the Perkin-Elmer Optima 3000 ICP atomic emission spectrometer are presented. The echelle-based polychromator with segmented-array charge-coupled device detectors enables the direct, visual examination of the overlapping lines Cd (I) 228.802 nm and As (I) 228.812 nm. The slit translation capability allows a large number of data points to be sampled, therefore, the advantage of noise averaging is gained. Pure spectra of each of the spectrally active components in the sample can be extracted through the GSAM calculation;An ICP is extracted into a small quartz vacuum chamber through a sampling orifice in a water-cooled copper plate. Optical emission from the Mach disk region is measured with a new type of echelle spectrometer equipped with two segmented-array charge-coupled-device detectors, with an effort to improve the detection limits for simultaneous multielement analysis by ICP-AES. The analyte line intensities are enhanced at higher pressure in the expansion chamber.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
1995

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Luan, Shen
Advisor dc:contributor.advisor
  • R. S. Houk

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/11014/
Dc Identifier Other
12013
6430565
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/11014/r_9606621.pdf|||Fri Jan 14 18:40:36 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Luan, Shen. Inductively coupled plasma spectrometry: noise characteristics of aerosols, application of generalized standard additions method, and Mach disk as an emission source. dissertation thesis, 1995. https://doi.org/10.31274/rtd-180813-10152