Back to search

Iowa State University

A field portable ultrasound system for bovine tissue characterization

Abstract

dc:description.abstract

<p>Efforts by beef producers and beef packers to reduce carcass losses and to move the industry to a value-based marketing system have renewed their interest in the development of new electronic grading techniques for assessing beef carcass composition. A custom ultrasonic data acquisition system has been developed for the purpose of investigating the feasibility of beef tissue characterization. The unit developed is a compact, hand-held, six channel battery-operated data logger capable of sampling A-mode ultrasound signals at a rate of 15 megasamples per second. A custom epoxy encapsulated ultrasound transducer array was developed to fit the inner curvature of the thoracic cavity on top of the intercostal muscle between the 12th and 13th rib. Data collected by the ultrasound unit is temporarily stored in a handheld data terminal/computer for retrieval and analysis on a personal computer at a later time. Ultrasound samples from 39 carcasses were analyzed for backscatter energy content. The ultrasound records were partitioned into two groups based on the contact characteristics between the probe and tissue. Preliminary fat estimation in the longissimus dorsi muscle have resulted in correlation coefficients on two partitioned data sets of 0.81 and 0.82. Preliminary marbling estimation in the longissimus dorsi muscle have resulted in correlation coefficients on two partitioned groups of 0.59 and 0.70.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemical and Biological Engineering
Year dc:date.issued
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Holland, Kyle
Advisors dc:contributor.advisor
  • David L. Carlson
  • Curran S. Swift

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/11027/
Dc Identifier Other
12026
6430578
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/11027/r_9606634.pdf|||Fri Jan 14 18:40:45 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Holland, Kyle. A field portable ultrasound system for bovine tissue characterization. dissertation thesis, 1993. https://dr.lib.iastate.edu/handle/20.500.12876/64239