Back to search

Iowa State University

Air mixing criteria for ceiling slot-ventilated agricultural enclosures

Abstract

dc:description.abstract

<p>The use of a scale-model is an effective technique to predict the performance of ventilation in full-scale prototypes. Many criteria have been proposed to simulate the behavior of airflow between scale-model and prototype. Because of the inconsistent results of past proposed similarity criteria, more validation work is needed to clarify the conflicts;Dimensional analysis using both the Buckingham Pi method and manipulating the governing differential equations was used to theoretically establish similarity parameters. Only partial similarity was reached since conflicts exist between proposed similarity parameters;Experiments of two scale models were conducted to study airflow similarity in ceiling slot-ventilated agricultural enclosures using different similarity criteria. The evaluation of similarity between scale-model and prototype included validation of penetration distance, airflow pattern, airspeed field, and temperature field using methods that included smoke visualization, airspeed field measurement, and temperature field measurement;The studies focused on the Reynolds number (Re) and inlet jet momentum ratio (Rm) as the similitude criteria for isothermal airflow, and Archimedes number (Ar) for nonisothermal airflow. The experimental results offer better agreement using Rm than using Re as the similitude criterion for isothermal airflow. Ar is an appropriate similitude criterion when the nonisothermal airflow pattern exhibits two-circulation airflow behavior. After the airflow is increased resulting in a single-circulation airflow, Rm associated with a similar heat load becomes the better similitude criteria;Future studies including improvement of the evaluation method, more complete investigation of the enclosure, variation of scale dimension and configuration layout, and better control of the experimental environment are recommended.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Agricultural and Biosystems Engineering (ENG)
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yu, Hsin
Advisor dc:contributor.advisor
  • Steven J. Hoff

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/11506/
Dc Identifier Other
12505
6455394
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/11506/r_9635372.pdf|||Fri Jan 14 18:52:03 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Yu, Hsin. Air mixing criteria for ceiling slot-ventilated agricultural enclosures. dissertation thesis, 1996. https://doi.org/10.31274/rtd-180813-10531