Back to search

Iowa State University

Effects of power ultrasound treatments on properties of Longissimus beef muscle

Abstract

dc:description.abstract

<p>This study was conducted to determine the effects of power ultrasound treatments on properties of Longissimus beef muscle. Twenty pairs of loins from steer carcasses, USDA Choice, maturity A were obtained 24hrs after slaughter for this study. Two experiments will be conducted at different intensity/time levels: (1) Control, 1.5 w/cm2, 3 w/cm2, and 5 w/cm2 for 3 minutes/side. (2) Control, 20 w/cm2, 40 w/cm2, and 60 w/cm2 for 45s/side (at 20 kHz) under refrigerated conditions. Each steak (four pieces) will be randomly allotted among these two experiments. Each loin was divided into at least 12 steaks and each steak was divided into 4 pieces, labeled, vacuum packed individually, and divided into groups: Day 1 and Day 7. Ultrasound treatments were applied using a direct probe commercial ultrasonic system. Cooking yields, shear force (Warner-Bratzler), and ultrasonic power entering the samples was measured. In addition, microscopy and SDS PAGE tests were conducted on the samples. No difference in shear force was observed for day 1, however at day seven the 5 w/cm2 treatment required a lower force (P < 0.05) to shear the sample. Histological cross-sectional samples for all treatments showed separation of the muscle bundles when compared with the control. SDS PAGE did not show any difference between treatments. Shear force values for day 1 were not significant, but showed a tendency toward lower shear values for the treated samples. At day 7, the shear force values were significant for the 40 w/cm2 treatment. The histological samples showed an evident separation of the muscle fibers. 5% gels indicated a possible degradation of titin at day 7.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Animal Science
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gonzalez, Gustavo
Advisor dc:contributor.advisor
  • Joseph C. Cordray

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/1432/
Dc Identifier Other
2431
6094331
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/1432/r_3105075.pdf|||Fri Jan 14 20:18:23 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gonzalez, Gustavo. Effects of power ultrasound treatments on properties of Longissimus beef muscle. dissertation thesis, 2003. https://doi.org/10.31274/rtd-180813-13229