Back to search

Iowa State University

Application of near-infrared spectroscopy for determination of nutrient contents in manure

Abstract

dc:description.abstract

<p>111 solid poultry layer, 95 solid poultry broiler litter, 39 swine solid hoop, 72 beef cattle, 85 swine slurry, and 88 swine liquid lagoon manure samples were collected from farms in three states. Samples were analyzed for total nitrogen (TN), ammonia nitrogen (NH3-N), phosphorus (P), and potassium (K) and total solids (TS) by traditional laboratory methods. The strong relationships of TN, NH3-N, P and K with TS were only found for K in swine lagoon manure and for P in swine slurry. Further, poor prediction performance was found in regression lines even with a strong relationship by using the ratio of standard deviation/standard error of prediction (RPD). These manure samples were also used to develop NIRS calibration models by using different mathematical data pretreatments. The R2 of the one-out cross validation for TS, TN, and NH3-N are between 0.80 and 0.97 for all manure samples. The R2 of the one-out cross validation for minerals range from 0.71 to 0.81, 0.50 to 0.78, 0.74 to 0.94, 0.66 to 0.91, 0.73 to 0.91, and 0.70 to 0.90 in poultry solid layer manure, poultry broiler litter, swine solid hoop, beef cattle, swine liquid lagoon, and swine slurry manure samples, respectively. The RPD values indicate NIRS can predict several minerals in certain manure samples, for example, P in beef cattle, swine lagoon, and swine slurry manure samples. Seventy-two beef cattle feedlot manure samples were scanned through the Foss NIRSystems 6500 (master) and the Foss NIRSystems 5000 (slave) instruments. Three standardization methods including cloning, direct standardization, and piece-wise direct standardization were used to transfer the master equations to slave spectra. The 72-sample data set was split into a 30-sample standardization set to generate standardized files and a 42-sample prediction set to test the accuracy of different standardization methods. The standard error of difference (SED) of the standardized slave spectra was much less than the corresponding SED of the unstandardized slave spectra. It was concluded that NIRS can determine TS, VS, TN, NH3-N, and possibly some minerals in manures rapidly and accurately, and the transfer of manure sample calibrations between instruments is possible.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Agricultural and Biosystems Engineering (ENG)
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ye, Wenyu
Advisor dc:contributor.advisor
  • Jeffery C. Lorimor

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/1479/
Dc Identifier Other
2478
6094380
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/1479/r_3105122.pdf|||Fri Jan 14 20:26:23 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ye, Wenyu. Application of near-infrared spectroscopy for determination of nutrient contents in manure. dissertation thesis, 2003. https://doi.org/10.31274/rtd-180813-12066