Back to search

Iowa State University

A time-domain model for predicting aerodynamic loads on a slender support structure for fatigue design

Abstract

dc:description.abstract

<p>Cantilevered signal, sign, and light support structures are used nationwide on major interstates, national highways, local highways, and at local intersections for traffic control purposes. Recently, there have been a number of failures of these structures that can likely be attributed to fatigue. In light of the fact that there is considerable uncertainty in the calculation of vortex shedding loads in both the American Association of State Highway and Transportation (AASHTO) and the Canadian Highway Bridge Design Code (CAN/CSA) code provisions, the current equations used for vortex shedding fatigue design need to be reevaluated and likely re-formulated or modified.;A luminary support structure or High Mast Light Pole (HMLP) is generally susceptible to two primary types of wind loading induced by natural wind gusts or buffeting and vortex shedding, both of which excite the structure dynamically and can cause fatigue damage. Vortex shedding is a unique type of wind load that alternatively creates areas of negative pressures on either side of a structure normal to the wind direction. This causes the structure to oscillate transverse to the wind direction.;The primary objective of this study was to develop a procedure for predicting wind loads in the time domain for the fatigue design of slender, tapered luminary support structures. To accomplish this, monitoring of long-term response behavior of a HMLP subjected to wind-induced vibration was needed. This was accomplished by full-scale measurement of the response of a HMLP located near Mason City next to I-35 in Iowa. Wind tunnel testing was also conducted to determine the required aerodynamic parameters of the pole cross section. Further, these aerodynamic parameters were cast into a coupled dynamic model for predicting the response of any HMLP in the time. Finally, the model was validated by comparing its results with the data collected from field monitoring.;Fatigue life of the given HMLP was estimated with further modeling of the wind speed distribution and stress amplitudes predicted by the time-domain model. The predicted fatigue life was compared with those calculated with the full-scale data.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Civil, Construction and Environmental Engineering
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chang, Byungik
Advisors dc:contributor.advisor
  • Brent M. Phares
  • Partha P. Sarkar

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/15583/
Dc Identifier Other
16582
7037511
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/15583/3289385.PDF|||Fri Jan 14 20:43:18 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Chang, Byungik. A time-domain model for predicting aerodynamic loads on a slender support structure for fatigue design. dissertation thesis, 2007. https://doi.org/10.31274/rtd-180813-16799