Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

Abstract

dc:description.abstract

<p>The focus of this dissertation is the development of techniques with which to enhance the existing abilities of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique has certain strengths and weakness. Attempts are made to improve upon those strengths and to overcome certain weaknesses.;One standout figure of merit for ICP-MS is limit of detection. With today's advances in instrumental hardware the limit of detection is often limited by the purity of the blank. While the limit of detection itself is not evaluated, by improving blank cleanliness it is theoretically possible to get improvements in this area. A metal-free, low-pressure, electrochemically modulated liquid chromatography (EMLC) column was designed and evaluated specifically for use on-line with ICP-MS. The EMLC column reduces levels of trace elements in blank solutions just before the blank is introduced into the nebulizer. The stationary phase is reticulated vitreous carbon (RVC), and the reference and counter electrodes are positioned upstream from the column to minimize contamination. Many metal ions can be removed at a single applied potential of ∼-0.75 V (vs SHE).;Analysis of samples with high matrix concentrations is a relative area of weakness for ICP-MS. Solution samples with matrix concentrations above ∼0.1% generally present difficulties due to cone clogging and matrix effects. Flow injection (FI) is coupled to ICP-MS to reduce clogging from samples such as 1% sodium salts and seawater. Surprisingly, matrix effects are also less severe during flow injection, at least for some matrix elements on the particular instrument used. Sodium chloride at 1% Na and undiluted seawater cause only 2 to 29% losses of signal for typical analyte elements. A heavy matrix element (Bi) at 0.1% also induces only ∼14% loss of analyte signal. However, barium causes about the same matrix effect as usual. Also, matrix effects during FI are of the usual magnitude when a metal shield is inserted between the load coil and torch, which is the most common mode of operation for the particular ICP-MS device used.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gross, Cory
Advisors dc:contributor.advisor
  • Robert S. Houk
  • Patricia Thiel
  • Hans Stauffer

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/15810/
Dc Identifier Other
16809
7045101
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/15810/3316165.PDF|||Fri Jan 14 20:47:04 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Gross, Cory. Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS. dissertation thesis, 2008. https://doi.org/10.31274/rtd-180813-17013