Back to search

Iowa State University

Development of a multi-frequency dielectric sensing system for real-time hay and forage moisture measurement

Abstract

dc:description.abstract

<p>A previous study at Iowa State University has shown promise for the determination of hay and forage moisture content prior to compaction using multi-frequency dielectric measurements. This previous study used a sensing system to take sequential frequency measurements which takes considerable time. Due to the fast material flow through equipment, the measurements need to be taken in a very short time period. Taking multi-frequency dielectric measurements "simultaneously" will ensure all frequencies measurements are from the same sample mass. This study has shown 1 MHz, 3 MHz, 7 MHz, and 13 MHz frequencies extracted from a multi-frequency signal are capable of providing the same signal information as sequentially scanned frequencies in milliseconds rather than multiple seconds. Hay bale moisture sensing was performed at Stardell Farms in Fredericksburg, Iowa, and the University of Wisconsin Arlington Research Station in Arlington, Wisconsin. Sensor plates were insulated and contained a guard plate around and behind them. Stardell Farms had the sensor plates 49.6 cm apart on a table top and Arlington had the sensor plates 36.8 cm apart in a fabricated bale chamber. Density independent moisture predictions were considerably better at Arlington with an adjusted R² = 0.80 and RMSE = 1.0 %MC wet basis for best sequential frequency combination 3 and 13 MHz. Arlington's density independent moisture prediction has an adjusted R² = 0.79 and RMSE = 1.0 %MC wet basis for best extracted frequency combination of 3, 7, and 13 MHz. Stardell Farms yielded a density independent adjusted R² = 0.68 with 7.4 %MC wet basis for best frequency combination of 7 MHz. The best extracted frequency combination of 3, 7, and 13 MHz yielded an adjusted R² = 0.67 with 7.5 %MC wet basis. At both locations the adjusted R² and RMSE was slightly higher for the sequential frequency combinations. At Stardell Farms the adjusted R² increased as the density increased while the adjusted R² remained approximately the same at Arlington regardless of density.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
None
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Benning, Ryan

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/18864/
Dc Identifier Other
19864
14540653
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/18864/Benning_ISU_2005_B466.pdf|||Fri Jan 14 21:47:12 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Benning, Ryan. Development of a multi-frequency dielectric sensing system for real-time hay and forage moisture measurement. thesis thesis, 2005. https://dr.lib.iastate.edu/handle/20.500.12876/72810