Measurement agreement between two activity monitors and a self-report recall measure under free-living conditions

Abstract

dc:description.abstract

<p>The available methods of assessing PA and energy expenditure (EE) under free-living conditions have shown limitations; therefore, the development of new tools is a necessity. Purpose: 1) The purpose of this study is to evaluate the agreement of two pattern recognition monitors during a variety of free-living activities, including at least 30 min. of moderate and vigorous PA and 2) to evaluate the ability of participants to recall information about the physical activity that they performed using a physical activity recall instrument. Methods: 20 participants (mean age 29.9± 5.7) wore the Intelligent Device for Energy Expenditure and Activity (IDEEA) and Armband (SP2) monitors during a whole day (2 trials). The following day, a physical activity recall interview (24PAR) was administered to each of the participants. During one of their two trials the participants were asked to record their activities in a diary. Results: The IDEEA, SP2 and 24PAR yielded similar total EE estimates (1990±557, 1928±539 and 2092±650 kcal/day, respectively) but estimates of PA were more variable (149.9±78.5, 170.3±74.8 and 111.5±73.2, respectively). The 24PAR estimates of EE and PA were significantly different compared to the IDEEA (P<0.05) and SP2 (P<0.01); however the effect sizes were small. Correlations among the three instruments were high for total EE (r=0.81 to r=0.91), but lower for PA estimates (r=0.59 to r=0.14). No differences were observed when comparing diary vs. non-diary trials for total EE but correlations for PA measures were higher for the diary trial. Correlation values for total sitting time between estimates from the IDEEA and 24PAR were high (r=0.81, P<0.0001). Conclusions: the SP2 was found to be a valid instrument to measure total EE and PA under free-living conditions. The 24PAR showed to be a valid tool to measure total activity and sitting time. In this study, the use of a dairy to improve recalls accuracy proved to be helpful only when recalling minute</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Exercise and Sport Science, Biological Basis of Physical Activity
Department dc:contributor.department
Department of Kinesiology
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Calabro, Miguel

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/19373/
Dc Identifier Other
20372
18210197
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/19373/Calabro_ISU_2006_C35.pdf|||Fri Jan 14 21:55:53 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Calabro, Miguel. Measurement agreement between two activity monitors and a self-report recall measure under free-living conditions. thesis thesis, 2006. https://doi.org/10.31274/rtd-20200622-22