Nonlinear device characterization using harmonic load pull measurement

Abstract

dc:description.abstract

<p>There has been a large amount of work and effort in the area of high and medium power MMICs recently. Today nonlinear microwave active devices such as power amplifiers can still benefit from better performance (such as power output and efficiency) by having suitable terminations at various harmonic frequencies. On the other hand, sub-harmonic terminations can affect the stability of the device. The main reason lies in the nonlinear behavior of the device that causes the device to generate various harmonic frequencies apart from the fundamental frequency.;Harmonic Balance (HB) has been a widely used and by far the most popular method to solve for a steady state solution of a nonlinear microwave circuit. It is done by splitting the nonlinear circuit into two parts: a linear part consisting of all the linear circuit elements and a nonlinear part consisting of all the nonlinear parts. Voltages and currents at a number of ports at the interface between the linear and nonlinear part are then computed and matched together using Kirschoff s voltage and current Law; The result is a solution for the voltages and currents and their harmonics at all the ports. In order to use the harmonic balance method, we need some characterization or model of both the linear and nonlinear part. We already have a very good characterization in form of governing equations for the linear part (such as transmission lines, linear resisters, capacitors and inductors). That is not true for the nonlinear active device operating at a large signal level. We still lack a good and sound characterization method for the nonlinear device. This is what we are set to do in this paper. We use a large signal harmonic source/load pull system to present a variety of terminations to the nonlinear device. Measurements of some parameters (such as current, voltage or power variables) of the nonlinear device are performed. We make use of the measured data to come up with a large signal characterization of the nonlinear device that gives the relationship between signals at various frequencies (harmonics) in addition to the frequency of interest.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aimdilokwong, Atiwat
Advisor dc:contributor.advisor
  • Robert J. Weber

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/354/
Dc Identifier Other
1353
6069851
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/354/r_3051445.pdf|||Fri Jan 14 23:45:03 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Aimdilokwong, Atiwat. Nonlinear device characterization using harmonic load pull measurement. dissertation thesis, 2002. https://doi.org/10.31274/rtd-180813-10943