Back to search

Iowa State University

Indirect estimation of parameters in a flexible tube, pulsatile flow system

Abstract

dc:description.abstract

<p>A mathematical model of pulsatile flow and pressure in a flexible tube with a possible branch and stenosis, or constriction, was formulated. Solution of the model equations was performed by the finite element method and a numerical integration procedure. An in vitro experimental model of pulsatile flow in a flexible tube with a stenosis and a branch was devised to provide observed waveforms and directly measured vessel parameter values. The model response satisfactorily matched the experimental data and exhibited sensitivity to the parameters of interest: vessel compliance, peripheral resistance, and severity and location of the stenosis. The model response was not sensitive to the vessel radius;The Gauss-Newton algorithm was used to minimize the sum of squared error between model response and experimental waveforms by varying the model parameters. Validation of the parameter estimation technique was performed by solving the model equations with measured values assumed for the system parameters and using the resulting waveforms in place of measured data. The vessel radius could not be estimated due to lack of sensitivity. The remaining parameters of interest could be reliably estimated except in the case of a mild stenosis, for which the stenosis location could not be estimated.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Engineering Science and Mechanics
Year dc:date.issued
1981

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gray, Timothy

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/6910/
Dc Identifier Other
7909
6298619
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/6910/r_8128821.pdf|||Sat Jan 15 01:30:50 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation