Iowa State University
Assessment of Concrete Pavement Curling and Warping Behavior in Iowa using High-speed Profiler Measurements
Abstract
dc:description.abstractCurling and warping behavior due to temperature and moisture variation has been widely considered an influential factor affecting the smoothness of jointed plain-concrete pavement (JPCP). In recent decades, while extensive efforts have been made to quantify the impact of curling-and warping-related deflections on the smoothness of JPCP, a standardized method for characterizing the effects of environmental factors on JPCP smoothness is still unavailable. This study aims to determine how to decrease the impact of curling and warping behaviors. In this study, we plan to use an SSI (Surface Systems and Instruments, Inc) high-speed profiler to scan pavement surfaces to collect raw profile data of concrete pavements and apply an advanced computational algorithm for processing the pavement profile data. We aim to evaluate and quantify curling and warping impact on Iowa concrete pavement and develop actionable recommendations for pavement design engineers and contractors. The proposed actions will be able to minimize the degree of curling and warping and correct curling- and warping-related performance issues. Validated algorithms based on Second-Generation Curvature Index (2GCI) model and second-order polynomial model were coded to evaluate the curling and warping degrees in multiple ways. Long Term Pavement Performance (LTPP) sections, highways, county roads, and city streets with various slab structures and mix design features were selected at different daily times and four seasons from a total of 36 sites in Iowa. This study used statistical and sensitivity analyses to select the variables significantly affecting curling and warping behaviors. AASHTO Pavement ME software predicted an equivalent temperature-difference model. The extended trendline virtually crosses the zero point for the overall equivalent temperature difference, indicating that the hypothesis of using “-10 °F” as the effective permanent curling and warping temperature difference for curled-up sites is appropriate. Morning appears to be the time of day where most curling and warping effects occur. The effects of engineer-controlled parameter considerations outweigh seasonal and diurnal environmental influences.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- thesis
- Discipline thesis:degree_discipline
- Civil engineering
- Department dc:contributor.department
- Department of Civil, Construction and Environmental Engineering
- Grantor
- Iowa State University
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tian, Kexin
- Advisors dc:contributor.advisor
-
- Ceylan, Halil
- Kim, Sunghwan
- Zhang, Wensheng
- Taylor, Peter
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://dr.lib.iastate.edu/handle/20.500.12876/7rKoPdkr