Performance of 2 1/4 Cr-1 Mo steel in a coal liquefaction dissolver vessel environment

Abstract

dc:description.abstract

<p>Smooth-bar and notched-bar tensile specimens of bainitic 2 1/4 Cr-1 Mo steel were exposed with and without an applied stress to argon gas or to a coal slurry-H(,2) environment for various conditions of time, temperature and pressure. Room temperature mechanical properties determined after each coal slurry-H(,2) exposure were compared to those of like samples exposed to the same conditions in argon. The coal slurry exposures produced very little change in the room temperature mechanical properties even after 1000 hours at temperatures as high as 426(DEGREES)C and total pressures of 27.6 MPa;Corrosion samples were exposed in both the liquid phase and the gaseous phase above the coal slurry-H(,2) environment. Scale growth rates, electron microprobe analyses and X-ray analyses of the scale region were obtained;Smooth-bar and notched-bar tensile specimens of normalized and tempered (bainitic) 2 1/4 Cr-1 Mo steel were exposed to hydrogen gas at 5.2 to 27.6 MPa in the temperature range from 482(DEGREES) to 593(DEGREES)C. Exposed samples were in three conditions: unloaded, with an applied load, or lightly prestrained. Applied stress, plastic deformation and increasing exposure times all lowered the temperature, at any given pressure, for the formation of hydrogen attack bubbles. The results have been plotted on Nelson Curve coordinates;Fatigue crack growth tests were conducted on normalized and tempered (bainitic) 2 1/4 Cr-1 Mo steel. Crack growth rates were determined for near threshold to intermediate growth rate regions at room temperature and 427(DEGREES)C. Testing was done in a partial vacuum, moist air, hydrogen and coal slurry gases. Crack growth rates for various hydrogen pressures were examined. The results suggest that corrosion products of the coal slurry gases may mitigate the tendency of hydrogen to enhance fatigue crack growth. Possible mechanisms are suggested;J integral tests were performed to determine JIC on normalizedand tempered (bainitic) 2 1/4 Cr-1 Mo steel. J values were obtainedfrom deep cracked compact tension specimens using single andmultiple specimen techniques. Testing was carried out in vacuum,argon, hydrogen and coal slurry gases at 427(DEGREES)C. Single specimentests were made using an electropotential crack growthmeasurement system described in detail. Values of J(,IC) for the singlespecimen tests are compared to those obtained from the multiple;specimen tests;('1)DOE Report IS-T-1024. This work was performed under ContractW-7405-Eng-82 with the Department of Oil, Gas, and Energy;</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Materials Science and Engineering
Year dc:date.issued
1982

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Woods, Charles

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/7555/
Dc Identifier Other
8554
6314536
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/7555/r_8224347.pdf|||Sat Jan 15 01:50:06 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Woods, Charles. Performance of 2 1/4 Cr-1 Mo steel in a coal liquefaction dissolver vessel environment. dissertation thesis, 1982. https://doi.org/10.31274/rtd-180813-5902