Back to search

Iowa State University

Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22

Abstract

dc:description.abstract

<p>One of the most effective techniques for augmenting in-tube condensation and evaporation is the use of internally finned tubes, specifically, tubes with small spiral fins, referred to as "micro-fin" tubes. The characteristic that distinguishes micro-fin tubes from other forms of internally finned tubes is that the fins are much smaller and more numerous. The present experimental study was divided into two phases, each of which involved the design, construction, and operation of two different test facilities;In the first phase, the effects of several geometrical parameters on two-phase thermal-hydraulic performance using a smooth tube and nine different micro-fin tubes were studied with R-113 as a test fluid on rather short (i.e., 41 in. or 1.0 m) length test sections. The geometrical parameters investigated were peak shape, valley shape, fin height, number of fins, and spiral angle. The micro-fin tube with 60 spiraled fins of 0.008 in. (0.20 mm) fin height, with a round tip and a flat valley shape, resulted in the best heat transfer performance for both evaporation and condensation;The local single-phase and evaporation enhancement factors (increase in heat transfer or pressure drop over the reference smooth tube) for 12.5 ft (3.81 m) long test sections were obtained by modifying the R-113 test apparatus. The results indicated comparable evaporation heat transfer enhancement factors for both short and long test sections;In the second phase, local single-phase and evaporation enhancement factors for R-22 were obtained using 12.1 ft (3.68 m) long electrically heated test tubes. A reasonable similarity was found between the local evaporation data for the two different refrigerants (i.e., R-113 and R-22). Finally, the R-22 test apparatus was modified to determine the average evaporation and condensation enhancement factors using a 12 ft (3.65 m) long shell-and-tube heat exchanger test section with refrigerant flowing in the tube and the water in the annulus;In summary, since these micro-fin tubes have excellent heat transfer performance (maximum enhancement factor of 3.8) with low penalties on the pressure drop (maximum enhancement factor of 1.8), they can be effectively used in refrigeration and air-conditioning equipment, specifically for heat pump applications.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Mechanical Engineering
Year dc:date.issued
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Khanpara, Jatin

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/8089/
Dc Identifier Other
9088
6328974
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/8089/r_8627124.pdf|||Sat Jan 15 02:05:51 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Khanpara, Jatin. Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22. dissertation thesis, 1986. https://doi.org/10.31274/rtd-180813-5781