Back to search

Iowa State University

Trace analysis of volatile organic compounds in water by GC and HPLC

Abstract

dc:description.abstract

<p>Low-molecular weight aldehydes and ketones were concentrated by a hydrophobic zeolite, ZSM-5. The carbonyl compounds (100 ppb) were desorbed with a small volume of acetonitrile and converted to the 2,4-dinitrophenylhydrazones. The derivatized analytes were recovered by solvent extraction (pentane) followed by microdistil- lation. The 2,4-dinitrophenylhydrazones were analyzed by reversed phase HPLC on a C(,18) column at 254 nm. Good recoveries were obtained for the model compounds, except formaldehyde. The method was applied to the analysis of drinking water from Ames, IA (no aldehydes or ketones) and from Des Moines, IA (1.6 ppb butanone);Other polar low-molecular weight compounds (100-200 ppb), diethyl ether, acetates, nitriles, alcohols, aldehydes, ketones and acids were concentrated by the ZSM-5 and Silicalite. Except for methanol, formaldehyde, acetic acid, and propionic acid good recoveries were obtained for model compounds. Concentration factors of 50 to 500 were achieved. Satisfactory desorbing solvents were 1-propanol, acetone, methanol and acetonitrile. The concen- trated solution was injected into a capillary (DBWax, 0.525 mm I.D.) column. The analytes were quantitated by GC with FID;The method of distillation with gas purging (helium) concentrated a variety of classes of organic (amines, alcohols, ketones, aldehydes, esters, phenols, nitriles, chlorinated compounds and polynuclear aromatic) compounds (25 ppm to 25 ppb). The entire apparatus was heated to 85(DEGREES)C or greater. The concentrating column (Tenax) was cooled. For safety a slow heating procedure was devised. The analytes were desorbed from the concentrating column by solvent elution with methanol or acetonitrile. The concentrated solution was injected into a capillary (methyl silicone, 0.525 mm I.D.) column and the analytes were quantitated by GC with FID;Recovery of the analytes was primarily dependent on the water solubility and molecular weight of the analyte. Less sample (more;headspace) was used for the strawberry jello, instant decaffeinated coffee, and shale oil retort water; ('1)DOE Report IS-T-1265. This work was performed under Contract No. W-7405-Eng-82 with the Department of Energy.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ogawa, Ikue

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/8106/
Dc Identifier Other
9105
6328995
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/8106/r_8627141.pdf|||Sat Jan 15 02:06:47 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Ogawa, Ikue. Trace analysis of volatile organic compounds in water by GC and HPLC. dissertation thesis, 1986. https://doi.org/10.31274/rtd-180813-11529