Reduced order modelling in multimachine power systems

Abstract

dc:description.abstract

<p>Conventional techniques used for the assessment of transient and dynamic stability in multimachine power systems require the solution of a large number of ordinary differential equations describing the dynamics of the system generating units. Detailed representation of generating units results in a system of equations that are numerically stiff and of large dimensionality. As a result, the digital simulation of the entire system becomes excessively complex and uneconomical in terms of computer time;It has been recognized that coherency identification is a fundamental step in obtaining reduced order dynamic equivalent models for power systems. Two methods of coherency identification are presented in this dissertation, one based on a slow coherency approach and the other based on modal analysis. Improvements in the slow coherency approach are accomplished by a sensitivity based identification of the set of group-reference generators in the system, leading eventually to the sets of coherent generators. The second method uses the undamped system equations having a system matrix A. The eigenstructure of A is used to obtain a set of coherency indices, based on the root-mean-square values of variations in angular differences between pairs of generators. These coherency indices are compared with a coherency threshold to determine coherent groups of generators. Numerical examples are presented to illustrate and validate both techniques;With regard to the dynamic stability of multimachine power systems, a method based on singular perturbation theory is proposed for the simulation of models of high dimensionality and widely varying time constants. In this method, the state vector is partitioned into subsets of slow and fast variables, a perturbation parameter, (epsilon), is selected and the equations are expressed in their singular perturbation form. The time responses of the system are obtained by the use of the asymptotic expansions of the outer solution and the boundary layer correction of the perturbed equations;A numerical example using a single machine-infinite bus system is used to illustrate and validate the method. While promising results were obtained, the need for additional refinements was made evident.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
1982

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Grande-Moran, Carlos

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/8345/
Dc Identifier Other
9344
6333694
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/8345/r_8307748.pdf|||Sat Jan 15 02:10:10 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Grande-Moran, Carlos. Reduced order modelling in multimachine power systems. dissertation thesis, 1982. https://doi.org/10.31274/rtd-180813-7954