Back to search

Iowa State University

Electrochemical detection methods for biologically-active molecules

Abstract

dc:description.abstract

<p>Pulsed Amperometric Detection (PAD) has proven to be applicable to the determination of a number of organic compounds. One difficulty has been calibration of PAD for quantitative analysis over a wide concentration range. By pairing PAD in series with Conductivity Detection (CD), a much wider linear calibration range was found for carbohydrates and amino acids. Both compound groups were separated via anion-exchange chromatography and detected at Au electrodes;In an attempt to decrease amino acid detection limits, phenylthiohydantoin and methylthiohydantoin derivatives were examined. PAD was found to be more sensitive to these derivatives than the free amino acids. DC amperometry was also applicable to the thiohydantoin derivatives, with no instability or sensitivity loss with time observed. Detection limits as low as two picomoles were determined. Employment of a commercially available C-18 column allowed separation of nearly all amino acids using gradient elution liquid chromatography;Improvement in detection of underivatized amino acids was made by applying Pulsed Coulometric Detection (PCD) and Indirect Coulometric Adsorption Detection (ICAD). Both could be used following separation on anion-exchange columns. PCD was coupled with a glass reference electrode to allow anion-exchange separation of amino acids using gradient elution, and baseline perturbation during the gradient was minimal. Up to 20 amino acids were separated in less than one hour.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
1988

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Welch, Lawrence
Advisor dc:contributor.advisor
  • Dennis C. Johnson

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/8901/
Dc Identifier Other
9900
6344796
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/8901/r_8909203.pdf|||Sat Jan 15 02:19:02 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Welch, Lawrence. Electrochemical detection methods for biologically-active molecules. dissertation thesis, 1988. https://doi.org/10.31274/rtd-180813-8892