<p>One of the major problems in nondestructive evaluation (NDE) is the evaluation of flaw sizes and locations in a limited inspectability environment. In NDE x-ray radiography, this frequently occurs when the geometry of the part under test does not allow x-ray penetration in certain directions. Other times, the inspection setup in the field does not allow for inspection at all angles around the object. This dissertation presents a model based reconstruction technique which requires a small number of x-ray projections from one side of the object under test. The estimation and reconstruction of model parameters rather than the flaw distribution itself requires much less information, thereby reducing the number of required projections. Crack-like flaws are modeled as piecewise linear curves (connected points) and are reconstructed stereographically from at least two projections by matching corresponding endpoints of the linear segments. Volumetric flaws are modeled as ellipsoids and elliptical slices through ellipsoids. The elliptical principal axes lengths, orientation angles and locations are estimated by fitting a forward model to the projection data. The fitting procedure is highly nonlinear and requires stereographic projections to obtain initial estimates of the model parameters. The methods are tested both on simulated and experimental data. Comparisons are made with models from the field of stereology. Finally, analysis of reconstruction errors is presented for both models.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
dissertation
Department dc:contributor.department
Department of Electrical and Computer Engineering
Year dc:date.issued
1990

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wallingford, Richard
Advisor dc:contributor.advisor
  • John P. Basart

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/9904/
Dc Identifier Other
10903
6371605
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/9904/r_9110577.pdf|||Sat Jan 15 02:39:27 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Wallingford, Richard. Flaw reconstruction in NDE using a limited number of x-ray radiographic projections. dissertation thesis, 1990. https://doi.org/10.31274/rtd-180813-9422