Design and modeling of a vacuum drying system for a biodiesel pilot plant
Abstract
dc:description.abstract<p>The purpose of this research was to investigate the removal of water from oil and biodiesel fuel using a vacuum drying system. Water left in the oil will cause an incomplete reaction when producing biodiesel. The water can hydrolyze the triglycerides to diglycerides and form a free fatty acid. Also, water left in the biodiesel will cause fouling of the fuel handling system for diesel engines and corrosion of tanks and equipment. This research project examines the performance of the drying system at different vacuum settings, fluid temperatures, throttling pressures, and condenser flow rates in order to determine minimal conditions for meeting fuel moisture specifications. This meant performing preliminary research into current vacuum drying systems and consulting venders on chosen equipment based on initial research and modeling. A biodiesel vacuum drying system was constructed and built at the Biomass Energy Conversion (BECON) Facility in Nevada, Iowa. A model of a vacuum drying system was developed in order to determine the proper equipment needed for the desired moisture removal at various conditions. Modeling of the vacuum drying system consisted of an energy and mass balance around the important components of the system, along with important assumptions and theories such as, the theory of ideal solutions and thin film theory. The model of the vacuum drying system and the actual system were compared, while determining the limits and assumptions of the model and drying system. The tests were carried out in a vacuum drying system at various conditions as the moisture percentages of the fuel and oil were monitored in order to determine the system performance. A series of experiments were conducted in order to investigate the effects of varying conditions on the drying system. The important factor investigated in these experiments was the moisture of the oil and fuel as the following conditions were varied. 1. Flash tank vacuum pressure; 2. Flash tank input fluid temperature; 3. Throttling pressure of input flash tank fluid; 4. Condenser flow rate. The results from these tests provide important information for the prediction of drying system performance at various conditions. The data from the tests will help determine what system settings are needed to achieve the maximum efficiency of the drying system in terms of moisture removal.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- thesis
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Department of Mechanical Engineering
- Year dc:date.issued
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Menges, Kirk
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://dr.lib.iastate.edu/handle/20.500.12876/96870
- Identifier
- archive/lib.dr.iastate.edu/rtd/19503/
- Dc Identifier Other
-
20502
18549526 - Mods Identifier Filename
- archive/lib.dr.iastate.edu/rtd/19503/Menges_ISU_2003_M463.pdf|||Fri Jan 14 21:57:23 UTC 2022