Back to search

Iowa State University

Destruction of Escherichia coli O157:H7 on whole apples via single and sequential application of chemical sanitizers

Abstract

dc:description.abstract

<p>This study was conducted to determine if single and sequential application of selected chemical sanitizers can achieve a 5-log reduction in Escherichia coli O157:H7 populations on apple surfaces. Sanitizers were utilized with and without mild heat to determine if increased temperatures would have an effect on sanitizer efficacy. Apples were spot-inoculated with a non-pathogenic strain of E. coli O157:H7, immersed in a sanitizer for 2 min and rinsed in distilled water for 5 sec. Chemical sanitizers used for single application were chlorine (200 ppm), hydrogen peroxide (5%), sodium bicarbonate buffer (pH 11.5), 1.5% H2O2 + 1.5% lactic acid, Tsunami100[superscript trademark symbol] (80 ppm) and ProSan[superscript trademark symbol] (1%). Among these chemical sanitizers, chlorine, 5% hydrogen peroxide, 1.5% hydrogen peroxide + 1.5% lactic acid, sodium bicarbonate buffer and Pro-San[superscript trademark symbol] were used sequentially on apple surfaces for 2 min per sanitizer. Bacterial populations were enumerated by duplicate plating on Tryptic Soy agar (TSA) and Sorbitol MacConkey agar (SMA) after 24 or 48 hr incubation at 35 or 370C. Populations of E. coli O157:H7 on apples immersed in (single) chemical sanitizers at 250C were reduced by 1.35 to 3.07 log10CFU/apple (TSA) and 1.82 to 3.77 log10CFU/apple (SMA). Log10 reductions for single treatments applied at 550C were 1.46 to 3.72 log10CFU/apple (TSA) and 2.31 to 3.90 log10CFU/apple (SMA). Sequential treatments at 250C eliminated E. coli O157:H7 by 2.10 to 3.17 log cycles based on TSA counts and 1.47 to 3.01 log cycles based on SMA counts. At 550C, E. coli O157:H7 populations were eliminated by 2.59 to 3.54 log cycles (TSA) and 1.96 to 3.27 log cycles (SMA). Single application of 1.5% hydrogen peroxide + 1.5% lactic acid and sequential application of chlorine (200 ppm) and 1.5% hydrogen peroxide + 1.5% lactic acid at 550C achieved the highest reductions of E. coli O157:H7 populations on apple surfaces at 3.90 and 3.27 log cycles (SMA), respectively. Results suggest that single and sequential application of chemical sanitizers were not effective in achieving a 5-log reduction of E. coli O157:H7 on whole apples based on conditions of the present study but can reduce the populations of the pathogen by approximately 4-log.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Food Science and Technology
Department dc:contributor.department
Food Technology
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Traynham, Toshiba

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/20068/
Dc Identifier Other
21067
18791862
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/20068/Traynham_ISU_2003_T73.pdf|||Fri Jan 14 22:19:24 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Traynham, Toshiba. Destruction of Escherichia coli O157:H7 on whole apples via single and sequential application of chemical sanitizers. thesis thesis, 2003. https://doi.org/10.31274/rtd-20200803-391