Back to search

Iowa State University

Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS

Abstract

dc:description.abstract

<p>The groundwork for coupling gradient liquid chromatography (LC) with inductively coupled plasma mass spectrometry (ICP-MS) is developed. An alternative method of quantification to isotope dilution is evaluated. Using a micronebulizer (100 [Mu]L/min) and the Apex-Q desolvation system from Elemental Scientific, Inc., samples containing up to 40% methanol are introduced to the plasma with lower destabilization effects than attributed to straight sample introduction. Samples are introduced by flow injection (FI) to evaluate peak broadening. The desolvation system broadens the FI peak from 2 to 25 s. Ion signal ratios are measured in the presence of increasing methanol concentration to simulate gradient elution. Analyte-internal standard (AIS) pairs are found whose signal ratios remain consistent (deviations < ±10%) over a methanol concentration range of 5 - 35%. Such deviations are similar to those found for natural isotopic pairs (63Cu/65Cu, 69Ga/71Ga, 203Tl /205T1) over the same concentration range. AIS pairs that remain consistent in simulated methanol gradients are tested in actual gradients. Those that show the best stability in simulated gradients (59Co/60Ni, 208Pb/205Tl) display equal signal ratio consistency in an 8% to 32% methanol gradient. High resolution trials are performed in order to remove polyatomic interferences for the AIS pairs whose ratios are inconsistent in low resolution (deviations above 10%). The addition of N2[subscript (g)] is shown to increase the tolerable amount of methanol that can be introduced to the desolvator. As a result, 75As+/125Te+ signal ratio values remain consistent throughout the entire methanol range studied. Quantification experiments are performed in low resolution using 60Ni as an internal standard, added post-column, to quantify Co in a store-bought sample of cyanocobalamin (vitamin B-12). The calculated concentration is determined to be 20% off the expected value.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Analytical Chemistry
Department dc:contributor.department
Department of Chemistry
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sullivan, Patrick

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/20940/
Dc Identifier Other
21939
20115410
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/20940/Sullivan_ISU_2006_S85.pdf|||Fri Jan 14 22:30:37 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Sullivan, Patrick. Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS. thesis thesis, 2006. https://doi.org/10.31274/rtd-20201107-497