Back to search

Iowa State University

Heat-treated poly(vinyl alcohol) membranes for bioseparations

Abstract

dc:description.abstract

<p>Heat-treated poly(vinyl alcohol) (PVA) membranes were fabricated for potential use in bioseparations. Poly(vinyl alcohol) is a hydrophilic polymer and therefore PVA membranes are expected to have high resistance to membrane fouling. Moreover, its semicrystalline structure provides good mechanical strength. The membranes were used to separate model macromolecules, FITC dextran and myoglobin, from a model small molecular weight solute, L-tryptophan. The membranes were heat-treated in an oven at 1000C for 1 hour to increase their crystallinity. The crystallinity of the membranes was measured using differential scanning calorimetry (DSC). The mechanical strength of the membranes was evaluated by measuring their compressive and tensile moduli using dynamic mechanical analyzer (DMA). The effects of heat-treatment, average molecular weight of PVA, stirring speed, membrane thickness, and addition of Pluronic[Registered trademark symbol] on the permeabilities of small molecular weight solutes across the PVA membranes were studied. The permeability studies were carried out using side-by-side diffusion cells. The mechanical strength and extent of fouling on these heat-treated PVA membranes were compared to commercial polyethersulfone (PeS) and regenerated cellulose membranes with molecular weight cut off of 10,000. It was found that the compressive moduli of swollen PVA membranes were comparable to PeS membranes, but it was higher than regenerated cellulose membranes. However, the tensile moduli of swollen PVA membranes with no backing supports were lower than the tensile moduli of PeS and regenerated cellulose membranes. Mapping of protein fouling on these membranes was measured qualitatively using diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). Regenerated cellulose membranes had significantly lower selectivities than PeS and PVA membranes. Both permeability and fouling studies indicated that PVA membranes had better fouling resistance than the commercial PeS and regenerated cellulose membranes. Asymmetric PVA membranes, prepared by utilizing the solubilities of PVA with two different degree of hydrolysis in water, did not give higher solute flux compared to the regular PVA membranes. However, their selectivities are comparable to the regular heat-treated PVA membranes.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Chemical Engineering
Department dc:contributor.department
Department of Chemical and Biological Engineering
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Amanda, Aurelia

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/21048/
Dc Identifier Other
22047
20252140
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/21048/Amanda_ISU_2000_A477.pdf|||Fri Jan 14 22:34:23 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Amanda, Aurelia. Heat-treated poly(vinyl alcohol) membranes for bioseparations. thesis thesis, 2000. https://doi.org/10.31274/rtd-20201118-12