Back to search

Iowa State University

The use of EP/TOMS total column ozone data in mesoscale analysis of convection

Abstract

dc:description.abstract

<p>High-resolution total column ozone data from the Earth Probe Total Ozone Mapping Spectrometer (EP/TOMS) are used in conjunction with potential vorticity (PV) from NCEP's Rapid Update Cycle (RUC) and Eta mesoscale model analyses to examine the role of stratospheric air and rapid PV fluctuations in two severe weather events accompanied by pronounced stratospheric intrusions. Backward trajectories, determined from the Eta model, were used to examine the role of descending dry stratospheric air in severe weather not associated with thunderstorms and within severe thunderstorms. Agreement between the total ozone and PV data supported the notion of stratospheric descent. Detailed vertical structure in the PV appears to be captured by small-scale variations in the total ozone. Also, the total ozone data identified mesoscale features that may be useful in model verification. In addition, the total ozone data was able to distinguish between PV of stratospheric origin and PV diabatically generated in the troposphere. Another severe weather event analyzed exemplifies the need to use chemical traces, such as ozone and water vapor, in addition to isentropic PV to indicate air mass origin. This particular case appeared to have enhanced total ozone concentrations unaccompanied by high PV values. Again, backward trajectories from the Eta model were used to discern the diabatic or diffusive processes that may have been responsible for the lack of correlation. These results are significant to tropospheric-stratospheric exchange studies indicating that isentropic PV alone is an insufficient indicator of air mass origin.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
thesis
Discipline thesis:degree_discipline
Meteorology
Department dc:contributor.department
Department of the Earth, Atmosphere, and Climate
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Goering, Melissa

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/21228/
Dc Identifier Other
22227
20252374
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/21228/Goering_ISU_2000_G64.pdf|||Fri Jan 14 22:35:48 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Goering, Melissa. The use of EP/TOMS total column ozone data in mesoscale analysis of convection. thesis thesis, 2000. https://doi.org/10.31274/rtd-20201118-192