Comparison of low refrigerant charge, air-coupled and hydronically coupled microchannel heat pumps with conventional systems

Abstract

dc:description.abstract

<p>Air-conditioning systems are significant contributors to the global climate change problem. Refrigerant leaks during operation, maintenance, and improper disposal at the end of their useful life contribute to the ozone-depletion and global warming problem. In the present study, two novel concepts for residential and commercial heat pumps using microchannel evaporator and condenser were investigated: air-coupled and hydronically coupled systems. The thermodynamic simulation models for both air-coupled and hydronically coupled heat pumps in the cooling and heating modes were designed using Engineering Equation Solver software. Results show that the microchannel heat pump would provide heating and cooling in a package much smaller than conventional systems. Both air-coupled and hydronically coupled systems also result in significant reductions in refrigerant inventories compared to the round tube systems investigated in the present study. This concept is a new approach toward the design, fabrication and installation of heating and cooling equipment. The drastic reductions in size yield substantial first-cost savings. The lower refrigerant inventories will minimize CFC and HCFC releases to the atmosphere, thus alleviating the ozone-depletion and global warming problems.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
dissertation
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Department of Mechanical Engineering
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jiang, Yirong

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Identifier
archive/lib.dr.iastate.edu/rtd/21389/
Dc Identifier Other
22388
21345911
Mods Identifier Filename
archive/lib.dr.iastate.edu/rtd/21389/Jiang_ISU_2001_J54.pdf|||Fri Jan 14 22:36:58 UTC 2022

Chain of custody

source
Harvested from
Iowa State University
Base URL
dr.lib.iastate.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Jiang, Yirong. Comparison of low refrigerant charge, air-coupled and hydronically coupled microchannel heat pumps with conventional systems. dissertation thesis, 2001. https://doi.org/10.31274/rtd-20210128-5