Iowa State University
Stabilization and variability of field parameters and polycyclic aromatic hydrocarbons in groundwater at former manufactured gas plant (FMGP) sites using low-flow sample collection methods
Abstract
dc:description.abstractTemperature, dissolved oxygen, specific conductance, oxidation-reduction potential, turbidity, and pH were monitored using a flow-through cell during purge events, while groundwater samples were collected throughout the purge event for polycyclic aromatic hydrocarbons (PAH) analyses at two FMGP sites. Low-flow sample collection methods were used with pump rates between 100 and 1000 mL/min. Dedicated submersible pumps were used at one site while a peristaltic pump was used at a second site. No trends in PAH concentrations during the purge event were found. No correlations between the groundwater field parameters monitored and PAH concentrations were identified. Most PAH concentrations were within laboratory analytical error during the purge event. The results of this fieldwork indicated that parameters may be recorded for stabilization every 3 to 5 minutes. However, sample collection may occur at any time during the purge event for the wells sampled in this study, regardless of parameter stabilization since no trends in analyte concentrations were found during the purge event. Dissolved oxygen levels were much more appropriate when monitored using low-flow sampling (DO I mg/L) than when sampling using a bailer (DO 10 mg/L). Turbidity levels were also much lower when sampled using low-flow methods as opposed to using a bailer. Monitoring temperature to stabilization did not appear to be necessary due to the degree to which ambient air temperatures affected the temperature measurement. Low-flow sampling methods appeared to work well for the two sites studied. The results and conclusions drawn from this fieldwork, however, may be different for other sites having different hydrogeological characteristics. At the two sites sampled for this fieldwork, the wells were very productive. At sites where the recharge is slow, stabilization of groundwater field parameters and turbidity levels <10 NTUs may be difficult to achieve.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Department thesis:degree_department
- Department of Civil, Construction and Environmental Engineering
- Year dc:date.issued
- 1999
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Holland, Mary Elizabeth
- Advisors dc:contributor.advisor
-
- Kjartanson, Bruce H.
- Ong, Say Kee
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- https://dr.lib.iastate.edu/handle/20.500.12876/WwPg984z